PIONEERPOS G24-LC manual RING/+CRING Indication, +CRC Parameters, At+Crc? +Crc

Models: G24-LC G24-L

1 444
Download 444 pages 51.67 Kb
Page 82
Image 82

Call Control

 

 

 

 

Command

Syntax

Response/Action

Remarks

Type

 

 

 

 

 

 

 

 

 

 

 

Set

+CRC=[<n>]

OK

The Set command enables/disables the

 

 

 

extended format of an incoming call

 

 

 

indication. When enabled, an incoming

 

 

 

call is indicated to the terminal with an

 

 

 

unsolicited result code

 

 

 

+CRING:<type> instead of the normal

 

 

 

RING.

 

 

 

 

Read

+CRC?

+CRC: <n>

The Read command queries the current

 

 

OK

settings for the cellular result code.

 

 

 

 

Test

+CRC=?

+CRC: (list of supported <n>s)

The Test command returns the possible

 

 

 

<n> values.

 

 

 

 

 

 

 

 

RING/+CRING Indication

+CRING: <type> or:

RING

The following table shows the +CRC parameters.

 

 

Table 3-7: +CRC Parameters

 

 

 

<Parameter>

 

Description

 

 

 

 

 

 

<n>

0

Extended format disabled

 

1

Extended format enabled

 

The default value is 0.

 

 

<type>

Type of incoming call:

ASYNCCSD

asynchronous transparent

REL ASYNCCSD

asynchronous non-transparent

FAX

Fax class 1

VOICE

Normal voice

ALT

Fax/voice

 

 

 

 

 

 

Example

AT+CRC? +CRC: 0

OK AT+CRC=? +CRC: (0-1)

OK

Example - RING/+CRING indication (..Incoming Data Call..)

RING

RING