Modem Configuration and Profile

 

 

 

 

Command Type

Syntax

Response/Action

Remarks

 

 

 

 

 

 

 

 

Set

ATS102 = <value>

OK

The Set command sets the delay before

 

 

 

sending data to the terminal, and

 

 

 

defines a period between sending the

 

 

 

wakeup signal and sending data to the

 

 

 

terminal.

 

 

 

 

Read

ATS102?

<value>

The Read command returns the current

 

 

OK

value.

 

 

 

 

 

 

 

 

The following table shows the S102 parameters.

 

Table 3-136: S102 Parameters

 

 

<Parameter>

Description

 

 

 

 

<value>

0 <= value <= 255

 

The default value is 30 ms.

 

 

 

 

Example

ATS102? <enter> 030

OK

ATS102=100 <enter>

OK

ATS102? <enter> 100

OK

(This means if there is data for transmission to the terminal, the G24-L drops the Wakeup Out line, waits 100 ms. and then sends data to the terminal.)

S100, Set Minimum Time for Terminal to Fall into Sleep Mode

ATS100 is a terminal minimum time limit for entering sleep mode.

In order to limit the number of interrupts on the DTE side and reduce data sending delay time on our side, G24-L sends wakeup-out pulse when the interval between one burst of sent/received data to the other is bigger than specified in ATS100.

 

 

 

 

 

 

Command Type

Syntax

Response/Action

Remarks

 

 

 

 

 

 

 

 

 

 

 

Set

ATS100=<delta>

OK

The set command sets the terminal

 

 

 

Or

minimum time limit for entering sleep

 

 

 

+CME ERROR: <err>

mode.

 

 

 

 

 

 

Read

ATS100?

<delta>

The Read command returns the current

 

 

 

OK

ATS100 value.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3-204

G24-L AT Commands Reference Manual

April 15, 2008

Page 268
Image 268