SMS

 

 

 

 

Command

Syntax

Response/Action

Remarks

Type

 

 

 

 

 

 

 

 

 

 

 

Read

AT+CSMP?

+CSMP:

The read command returns the current

 

 

<fo>,<vp>,<pid>,<dcs>

parameters value.

 

 

OK

 

 

 

or:

 

 

 

+CMS ERROR: <err>

 

 

 

 

 

Test

AT+ CSMP =?

OK

The test command just returns OK.

 

 

or:

 

 

 

+CMS ERROR: <err>

 

 

 

 

 

 

 

 

 

The following table shows the +CSMP parameters.

 

Table 3-46: +CSMP Parameters

 

 

<Parameter>

Description

 

 

 

 

<fo>

first octet of GSM 03.40. in integer format. For detailes see +CMGW definitions.

 

The default value at power-up is 17 (Message type is: SMS-SUBMIT and relative VP

 

format).

 

 

<vp>

Validity Period. depending on SMS-SUBMIT <fo>, TP-Validity-Period-Format bits

 

setting. Either in integer format (see Table 3-47) or in time-string format

 

("yy/MM/dd,hh:mm:ss±zz").

 

If there is no correlation between the VPF and the VP value. an error message will be

 

returned.

 

 

<pid>

Protocol-Identifier. The one octet information element by which the SM-TL either

 

refers to the higher layer protocol being used, or indicates interworking with a certain

 

type of telematic device.

 

"0 - no interworking, SME-to-SME protocol (default)

 

"Any value between 0-255 will be accepted.

 

The SC may reject messages with a TP-Protocol-Identifier containing a reserved

 

value or one, which is not supported.

 

 

<dcs>

One octet of Data Coding Scheme, indicates the data coding scheme of the DATA,

 

and may indicate a message class.

 

NOTE:

 

For DCS expanded information, see “DCS handling” on page 3-113.

 

default alphabet: 00xx00xx, 111100xx, 1101xxxx

 

8 bit data: 00xx01xx, 111101xx

 

UCS2: 00xx10xx, 1110xxxx

 

reserved: 00xx11xx, 0100xxxx-1011xxxx

 

The default value at power-up is 0 - Default alphabet.

 

 

 

 

 

 

Table 3-47: VP Relative Format (In Integer Format)

 

 

 

 

<Parameter>

Description

 

 

 

 

 

 

 

0 to 143

(TP-VP + 1) x 5 minutes (i.e. 5 minutes intervals up to 12 hours)

 

 

 

 

144 to 167

12 hours + ((TP-VP - 143) x 30 minutes)

 

 

 

3-80

G24-L AT Commands Reference Manual

April 15, 2008

Page 144
Image 144
PIONEERPOS G24-LC manual 46 +CSMP Parameters, VP Relative Format In Integer Format