PIONEERPOS G24-LC manual Parameter Description P1,P2, P2 Mode

Models: G24-LC G24-L

1 444
Download 444 pages 51.67 Kb
Page 282
Image 282

UI (User Interface)

 

 

Table 3-144: +CRSM Parameters (Cont.)

 

 

 

 

 

<Parameter>

 

Description

 

 

 

 

 

 

 

<P1>,<P2>,

Integer type. Parameters passed on by the ME to the SIM. These parameters are man-

 

<P3>

datory for every command, except GET RESPONSE and STATUS.

 

 

READ BINARY

 

 

<P1> Offset high (0...255)

 

 

<P2> Offset low (0...255)

 

 

<P3> Length (0...255)

 

 

READ BINARY

 

 

<P1> Rec. No. (0...255)

 

 

<P2> Mode

"02" = next record

 

 

 

"03" = previous record

 

 

 

"04" = absolute mode/current mode, the record

 

 

 

number is given in P1 with P1='00' denoting

 

 

 

the current record.

 

 

<P3> Length (0...255)

 

 

GET RESPONSE

 

 

<P1> "00"

 

 

 

<P2> "00"

 

 

 

<P3> Length (0...255)

 

 

UPDATE BINARY

 

 

<P1> Offset high (0...255)

 

 

<P2> Offset low (0...255)

 

 

<P3> Length (0...255)

 

 

UPDATE RECORD

 

 

<P1> Rec. No. (0...255)

 

 

<P2> Mode

"02" = next record

 

 

 

"03" = previous record

 

 

 

"04" = absolute mode/current mode, the record

 

 

 

number is given in P1 with P1='00' denoting

 

 

 

the current record.

 

 

<P3> Length (0...255)

 

 

STATUS

 

 

 

<P1> "00"

 

 

 

<P2> "00"

 

 

 

<P3> Length (0...255)

 

 

 

 

<data>

Information which shall be written to the SIM (hexadecimal character format). Man-

 

 

datory for UPDATE BINARY and UPDATE RECORD.

 

 

 

 

3-218

G24-L AT Commands Reference Manual

April 15, 2008

Page 282
Image 282
PIONEERPOS G24-LC manual Parameter Description P1,P2, P2 Mode