Rheem AP13731 warranty Horizontal Vent Terminal Location, US Installations

Models: AP13731

1 36
Download 36 pages 16.68 Kb
Page 15
Image 15

Installing the water heater.

D

E

V B

V

L

G

v

A

 

C

v

FIXED

ED

 

OS

 

CL

 

LE

 

ERAB

 

OP

v

 

F

 

 

B

H

 

 

 

B

v

B

 

 

D

 

 

FIXE

 

 

 

 

SED

 

 

 

RABLE

CLO

 

 

 

OPE

 

 

 

v

 

 

 

B

 

v

 

X

 

 

 

 

 

 

 

 

B

A

J

 

 

 

 

 

 

 

 

I

v

X

K

M

 

V VENT TERMINAL

X AIR SUPPLY INLET

AREA WHERE TERMINAL IS NOT PERMITTED

Horizontal Vent Terminal Location

The following information should be used for determining the proper location of the vent terminal for indoor and outdoor tankless water heaters.

 

 

 

 

 

Canadian Installations 1

US Installations 2

 

 

 

 

 

 

 

 

 

A=

Clearance above grade, veranda,

 

12 inches (30 cm) above anticipated

 

12 inches (30 cm) above anticipated

 

 

 

porch, deck or balcony.

 

snow level.

 

snow level.

 

 

 

 

 

 

 

 

 

 

B=

Clearance to window or door that

 

6 inches (15 cm) for appliances < 10,000

 

4 feet (1.2 m) below or to side of

 

 

 

may be opened.

 

Btuh (3 kW), 12 inches (30 cm) for

 

opening; 1 foot (300 mm) above opening.

 

 

 

 

 

 

appliances > 10,000 Btuh (30 cm) for

 

 

 

 

 

 

 

 

appliances > 10,000 Btuh (30kW), 36

 

 

 

 

 

 

 

 

inches (91 cm) for appliances > 100,000

 

 

 

 

 

 

 

 

Btuh (30kW).

 

 

 

 

C= Clearance to permanently closed

 

*

 

*

 

 

window.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D=

Vertical Clearance to ventilated soffit

 

4 feet (1.2 m)

 

4 feet (1.2 m)

 

 

 

located above the terminal within a

 

 

 

 

 

 

 

horizontal distance of 2 feet (61 cm)

 

 

 

 

 

 

 

from the center line of the terminal.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E=

Clearance to unventilated soffit.

 

*

 

*

 

 

 

 

 

 

 

 

 

 

F=

Clearance to outside corner.

 

*

 

*

 

 

 

 

 

 

 

 

 

 

G=

Clearance to inside corner.

 

*

 

*

 

 

 

 

 

 

 

 

 

M = Clearance under veranda, porch,

 

3 feet (91 cm)

 

3 feet (91 cm)

 

 

 

 

deck or balcony.

 

 

 

 

 

 

 

 

 

 

1 In accordance with current CAN/CGA-B149 Installation Codes.

 

 

2 In accordance with current ANSI Z223.1/ NFPA 54 National Fuel Gas Code.

 

 

 

 

 

 

 

Canadian Installations 1

US Installations 2

 

 

 

 

 

 

 

 

H = Clearance to each side of center line

3 feet (91 cm) within a height 15 feet

*

 

 

 

 

extended meter/regulator assembly.

(4.57 m) above the meter/regulator

 

 

 

 

 

above

 

 

 

 

 

assembly.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I =

 

Clearance to service regulator vent

3 feet (91 cm)

*

 

 

 

 

outlet.

 

 

 

 

 

J =

 

Clearance to nonmechanical air

6 inches (15 cm) for appliances < 10,000

4 feet (1.2 m) below or to side of

 

 

 

supply inlet to the combustion air

Btuh (3 kW), 12 inches (30 cm) for

opening; 1 foot (300 mm) above opening.

 

 

 

inlet to any building or other

appliances > 10,000 Btuh (30 cm) for

 

 

 

 

 

appliance.

appliances > 10,000 Btuh (30kW), 36

 

 

 

 

 

 

 

inches (91 cm) for appliances > 100,000

 

 

 

 

 

 

 

Btuh (30kW).

 

 

 

 

 

 

 

 

 

 

 

 

K =

Clearance to mechanical air supply

6 feet (1.83 m)

3 feet (91 cm) above if within 10 feet (3

 

 

 

m) horizontally.

 

 

 

inlet.

 

 

 

 

 

 

 

 

 

 

 

L =

Clearance above paved side walk or

7 feet (2.13 m)

7 feet (2.13 m)

 

 

 

paved driveway located on public

 

 

 

 

 

 

 

property.

 

 

 

 

 

 

 

 

 

 

 

 

M = Clearance under veranda, porch,

Not Allowed

Not Allowed

 

 

 

deck or balcony.

 

 

 

 

+

A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and

 

 

serves both dwellings.

15

*

If clearances are not specified then follow local installation codes and the requirement of the gas supplier.

 

 