WARNING: Field wiring connections and electrical grounding must comply with local codes, or in the absence of local codes, with the latest edition of the National Electrical Code, ANSI/NFPA 70, or in Canada, Canadian Electrical Code, CSA C22.1 Part 1.
NOTICE: The provided remote control will allow a maximum temperature setting of 120°F (49°C).
Temperatures of up to 180°F (82°C) can be achieved with dip switch adjustment. Only qualified service personnel should perform this adjustment.
Remote Control Installation
One (1) remote control is provided with the water heater.
The following are considerations for determining the location of the remote control(s):
●DO NOT install any remote control outdoors or areas were it can come in contact with water.
●Place remote control out of children’s reach.
●The remote control can be installed in convenient locations such as the kitchen, laundry room, utility room, or directly beside the indoor water heater.
●Avoid areas where the remote control may be exposed to heat, e.g. stove ranges or heaters.
●Avoid areas where the remote control may be subjected to oil and/or steam from cooking.
●Avoid areas where chemical agents (such as thinner, benzine and alkaline) are used.
●Avoid areas of direct sunlight.
●The MAXIMUM distance between the water heater and the remote control installation location is limited to 195 feet (59 m) of wire.
NOTICE: Only main remote control
No other manufacturer’s controls are suitable for use with this water heater.
DO NOT attempt to disassemble the remote control.
Base Plate
MAIN
Control
| PRIORITY |
|
| |
| °F |
|
| |
| POWER |
|
| |
| ON/OFF |
|
| |
|
| Mounting Screw x 2 | ||
| Control screw |
|
| |
Remote Control | Remote Control | Temperature | Availability | |
Model Number | Description | Set Point Range | ||
| ||||
|
| 100°F - 120°F | Factory Default | |
|
| |||
MAIN |
| |||
125°F - 180°F | With Dip Switch | |||
|
| |||
|
| Adjustment |
NOTICE:
Manifolding Applications: Certain Commercial installations may require more than one water heater piped together in a manifold to supply enough capacity for high temperature and/or water flow applications. Special manifolding control kits are available for operating multiple heaters together. Contact your dealer for details.
19