The content on this page is intended for use by qualified

installation/service personnel ONLY.

WARNING: Improper adjustment, alteration,

! DANGER: Hotter water increases

service or maintenance can cause property damage,

the potential for Hot Water SCALDS.

personal injury, or death.

 

Temperature Setting DIP Switch Adjustment

Required adjustment for up to 180°F (82°C) water temperature settings

!WARNING: Refer to scald potential warnings on page 4 before making adjustment. Changing this setting is done at your own risk.

DO NOT alter the #4 DIP Switch if the setting of up to 180°F (82°C) is not required.

Follow the instructions below if it is determined that a setting of up to 180°F (82°C) is required.

Turn off remote control. Turn off the gas and water shutoff valves.

Remove the front cover.

Find the DIP Switch #4 located at the top left hand side of the PCB. (See illustration to the right for DIP Switch location)

Change the DIP Switch #4 setting to the “ON” position. DO NOT alter any other DIP Switch. The LED on the PCB is flashing. At the same time, the display of the Main Remote Control starts to flash.

Press the “Max” button on the left hand side of the PCB for more than 1 second. The LED on the PCB starts illuminating continuously. At the same time, the display of the Main Remote Control is on continuously.

Change the DIP Switch #4 setting back to the “OFF” position. DO NOT alter any other DIP Switch. The LED on the PCB will stop illuminating. At the same time, the display of the Main Remote Control will turn off.

Time/Temperature Relationship in Scalds

Water Temperature

 

 

 

Time To Produce a Seroius Burn

 

 

 

 

 

 

 

 

 

 

 

 

 

120°F (49°C)

 

 

 

 

 

 

More than 5 minutes

125°F (52°C)

 

 

 

 

 

 

 

1 ½ to 2 minutes

130°F (54°C)

 

 

 

 

 

 

 

About 30 seconds

135°F (57°C)

 

 

 

 

 

 

 

About 10 seconds

140°F (60°C)

 

 

 

 

 

 

Less than 5 seconds

145°F (63°C)

 

 

 

 

 

 

Less than 3 seconds

150°F (66°C)

 

 

 

 

 

 

 

About 1 ½ seconds

155°F (68°C)

 

 

 

 

 

 

 

 

About 1 second

Table courtesy of Shriners Burn Institute

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

DIP1

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

 

4

 

 

OFF

1

2

3

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Location of DIP Switches on PC Board.

Attach the unit’s front cover.

Turn on the remote control, gas and water shutoff valves.

Check and ensure safe operation and performance of the water heater.

See steps below to LIMIT maximum water temperature setting to 120 (49°C). Follow first four bullets points listed above, then continue as listed below:

Press the “Min.” button on the left hand side of the PCB for more than 1 second. The LED on the PCB starts illuminating continuously. At the same time, the display of the Main Remote Control is on continuously.

Change the DIP Switch #4 setting back to the “OFF” position. DO NOT alter any other DIP Switch. The LED on the PCB will stop flashing. At the same time, the display of the Main Remote Control turn off.

Attach the unit’s front cover.

Turn on the remote control, gas and water shutoff valves.

 

 

“Max”

Check and ensure safe operation and

 

 

Button

 

 

 

 

 

LED

performance of the water heater.

 

 

 

 

 

 

 

 

 

 

 

 

SW1

SW2

 

 

 

 

 

 

 

 

 

“Min.”

SW3

DIP1

 

 

ON

Button

 

 

 

 

OFF

 

1

2

3

4

DIP

Switches

ON

1 2 3 4

As set from factory

ON

1 2 3 4

Setting during adjustment

to DIP Switch #4 for temperature.

ON

1 2 3 4

Setting after adjustment

to DIP Switch #4 for temperature.

35

Page 35
Image 35
Rheem AP13731 warranty Temperature Setting DIP Switch Adjustment