Open
SW175
SW175
SW174W
SW174W
SW172
SW172
ST165
ST165
ST162
ST162
: An alarm is detected when the terminal status
is changed to “Off”.
Alarm output: Alarm output will be carried out according to the settings for “Alarm output terminal
setup” (®page 141).
Default: Off
[Terminal 3]
Determine how to use terminal 3.
Off: Not used.
Alarm input: Receives alarms.
Close
SW175
SW175
SW174W
SW174W
SW172
SW172
ST165
ST165
ST162
ST162
: An alarm is detected when the terminal status
is changed to “On”.
Open
SW175
SW175
SW174W
SW174W
SW172
SW172
ST165
ST165
ST162
ST162
: An alarm is detected when the terminal status
is changed to “Off”.
AUX output: AUX output will be supplied. The [AUX] buttons will be displayed on the “Live” page.
Default: Off
Note
AUX is a camera terminal that allows users to operate (Open/Close) arbitrarily from the “Live” page.
For example, an operator can remotely control lights in a place where the camera is installed by
connecting the terminal to the light controller.
Refer to the installation guide for further information about input/output rating of each terminal.
SW396
SW396
SW395
SW395
SC386
SC386
SC385
SC385
SC384
SC384
:
While “Alarm input” is being selected, an alarm is detected when the terminal status is changed to
“On”. (Default)
It is possible to configure the setting so that an alarm is detected when the terminal status is changed
to “Off”. Refer to the [Readme] file on the provided CD-ROM for further information about the setting.
Or refer to our website (http://panasonic.net/pss/security/support/info.html) for further information
about the supported software.
[VMD alarm]
When clicking “VMD >>”, the [VMD area] tab of the “Alarm” page will be displayed. (®page 143)
[Auto track alarm]
SW396
SW396
SC386
SC386
When clicking “Auto track setting >>”, the [Image/Position] tab of the “Camera” page will be displayed. The
setup menu will be displayed in a newly opened window. (®page 120)
[Command alarm]
Select “On” or “Off” to determine whether or not to receive the command alarm.
The command alarm is the function that provides notification of a Panasonic protocol alarm from the other
cameras. When “On” is selected, alarm actions will be performed between multiple cameras.
Default: Off
[Originating port number]
Select a port number to be used to receive the command alarm.
Available range: 1-65535
Default: 8181
The following port numbers are unavailable since they are already in use.
20, 21, 23, 25, 42, 53, 67, 68, 69, 80, 110, 123, 161, 162, 443, 554, 995, 10669, 10670, 59000-61000
Operating Instructions 135
13 Configure the alarm settings [Alarm]