Note
AUX is a camera terminal that allows users to operate (Open/Close) arbitrarily from the “Live” page.
For example, an operator can remotely control lights in a place where the camera is installed by
connecting the terminal to the light controller.
13.7 Configure the VMD settings [VMD area]
Click the [VMD area] tab on the “Alarm” page. (®page 47, page 49)
The video motion detection areas can be set on this page.
The VMD areas can be set up to 4 areas for each preset position (
SW395
SW395
SC385
SC385
SC384
SC384
SW175
SW175
SW174W
SW174W
SW172
SW172
ST165
ST165
ST162
ST162
: maximum 64 preset positions/
SW396
SW396
SC386
SC386
: maximum 256 preset
positions). When motion is detected in the set area, it will be regarded as an alarm. The camera can be
configured to take an alarm action even when the camera is not at the preset position.
IMPORTANT
The alarm occurrence indication button (®page 12) will be displayed when motion is detected by the
VMD function.
The alarm occurrence indication button will be displayed when receiving an alarm input of a terminal
alarm or a command alarm.
Depending on the network environment, notification may be delayed even when “Real time” is selected
for “Alarm status update mode” on the [Basic] tab of the “Basic” page (®page 53).
The motion detection function is not the dedicated function to prevent thefts, fires, etc. We are not
responsible for any accidents or damages occurring in case.
Operating Instructions 143
13 Configure the alarm settings [Alarm]