10.4 Configure the settings relating to the logs [Log](SW396/SW395/SC386/SC385/SC384/SW175/SW172/ST165/ST162)
Click the [Log] tab on the “Basic” page. (®page 47, page 49)
The settings relating to the log list can be configured in this section.

Alarm

Settings for the alarm log list can be performed.
[Save logs]
Select “On” or “Off” to determine whether to save the alarm logs.
On: Alarm logs will be saved.
Off: Alarm logs will not be saved.
Default: On
Note
When “H.264” is selected for “Recording format”, “On” or “Off” will automatically be selected for “Save
logs” according to the setting of “Save trigger”.
When “H.264” is selected for “Recording format” and when “Alarm input” is selected for “Save
trigger”, only alarm logs will be saved.
[Name of the destination directory for downloaded images]
Enter the name of the destination directory to which images associated with the logs are to be downloaded.
For example, enter “C:\alarm” to designate the folder “alarm” under drive C.
Available number of characters: 3 - 128 characters
Available characters: Alphanumeric characters, the backslash (\), the colon (:), the slash (/), and the
underscore (_).

Manual/Schedule

Configure the settings relating to manual saving or schedule saving of the log list.
Select “On” or “Off” and designate the destination folder in the same manner as for “Alarm”.
Operating Instructions 73
10 Configure the basic settings of the camera [Basic]