Table 8-1. Error Codes (continued)

Error Code

Description

User Action

 

 

 

DC

I2C Bus Failure

Contact technical support.

DD

Power Supply x fan has failed,

Check if the indicated fan is operational and not obstructed.

 

Redundancy may be at risk

Check ambient temperature conditions.

 

The subcode indicates which power

Power cycle the unit

 

supply fan is affected

If the error persists, contact technical support and replace

 

 

 

Subcode 01: 1st PS fan from bottom

power supply x.

 

Subcode 02: 2nd PS fan from bottom

 

 

 

 

DF

Power Good signal changed from 2 to 1

Check the Power Supply whose green LED is not lighting

 

Power Supplies

If the error persists, contact technical support and replace

 

 

 

 

power supply x.

 

 

 

F0

Drive Over temperature Condition

1. Check the ambient temperature conditions, and check all

 

 

 

The subcode indicates which drive is

fans.

 

2. If the error recurs, contact technical support.

 

affected.

 

 

 

Example:

 

 

Subcode 02: drive #2

 

 

 

 

F1

Drive Communication Error

Contact technical support.

 

Library controller has lost

 

 

communication to drive

 

 

The subcode indicates which drive is

 

 

affected.

 

 

Example:

 

 

Subcode 02: drive #2

 

 

 

 

F2

Drive Sled not present

1. Verify that the drive sled is properly installed in the

 

 

 

The subcode indicates which drive sled

library and that all associated cables are properly

 

connected, then retry the operation.

 

is affected.

 

2. If the error recurs, contact technical support.

 

 

 

Example:

 

 

Subcode 02: drive sled #2

 

 

 

 

Chapter 8. Error Codes 8-7

Page 175
Image 175
Dell TL2000 manual Error Code Description User Action