Table
Error Code | Description | User Action |
|
|
|
DC | I2C Bus Failure | Contact technical support. |
DD | Power Supply x fan has failed, | Check if the indicated fan is operational and not obstructed. |
| Redundancy may be at risk | Check ambient temperature conditions. |
| The subcode indicates which power | Power cycle the unit |
| supply fan is affected | If the error persists, contact technical support and replace |
|
| |
| Subcode 01: 1st PS fan from bottom | power supply x. |
| Subcode 02: 2nd PS fan from bottom |
|
|
|
|
DF | Power Good signal changed from 2 to 1 | Check the Power Supply whose green LED is not lighting |
| Power Supplies | If the error persists, contact technical support and replace |
|
| |
|
| power supply x. |
|
|
|
F0 | Drive Over temperature Condition | 1. Check the ambient temperature conditions, and check all |
|
| |
| The subcode indicates which drive is | fans. |
| 2. If the error recurs, contact technical support. | |
| affected. | |
|
| |
| Example: |
|
| Subcode 02: drive #2 |
|
|
|
|
F1 | Drive Communication Error | Contact technical support. |
| Library controller has lost |
|
| communication to drive |
|
| The subcode indicates which drive is |
|
| affected. |
|
| Example: |
|
| Subcode 02: drive #2 |
|
|
|
|
F2 | Drive Sled not present | 1. Verify that the drive sled is properly installed in the |
|
| |
| The subcode indicates which drive sled | library and that all associated cables are properly |
| connected, then retry the operation. | |
| is affected. | |
| 2. If the error recurs, contact technical support. | |
|
| |
| Example: |
|
| Subcode 02: drive sled #2 |
|
|
|
|
Chapter 8. Error Codes