Table
Error Code | Description | User Action | ||
|
|
|
| |
B3 | Accessor controller urgent stop due to a | 1. | Verify that the left and right magazines are completely | |
| released magazine | |||
|
| inserted, then retry operation. | ||
|
|
| ||
|
| 2. If the problem still exists, contact technical support. | ||
|
|
|
| |
B4 | Cartridge did not transport completely |
|
| |
| Gripper could not pick cartridge and CP |
|
| |
| sensor not present |
|
| |
| After pushing the cartridge, CP sensor | Contact technical support. | ||
|
|
| ||
| still not present |
|
| |
|
|
|
| |
B5 | Accessor controller does not respond on |
|
| |
| command |
|
| |
|
|
|
| |
C0 | Network initialization failed |
|
| |
|
| 1. Check network cable and network configuration, then | ||
C1 | Telnet Interface initialization failed | |||
| retry operation. | |||
|
|
| ||
C2 | Webserver initialization failed | 2. | ||
If the error recurs, contact technical support. | ||||
|
| |||
C6 | Ping command did not reach target | |||
|
| |||
|
|
|
| |
C7 | Cannot Upgrade from USB |
|
| |
|
|
|
| |
D0 | ROM error. ROM checksum incorrect |
|
| |
|
|
|
| |
D1 | RAM error. Power on Self Test ( POST ) |
|
| |
| has failed, |
|
| |
|
|
|
| |
D2 | NVRAM |
|
| |
| Memory) error. R/W operation to |
|
| |
| NVRAM has failed |
|
| |
|
|
|
| |
D3 | CTC (Channel to Channel ) Error. Timer |
|
| |
| unit has failed during POST. |
|
| |
|
| Contact technical support. | ||
D4 | UART (Universal Asynchronous Receiver | |||
| Transmitter ) Error. Frame overrun or |
|
| |
| Parity Error on serial Interface. |
|
| |
|
|
|
| |
D5 | Display Error |
|
| |
| Communication to display failed |
|
| |
|
|
|
| |
D6 | Memory Error, Stack and heap overflow. |
|
| |
|
|
|
| |
D7 | Fatal system error |
|
| |
|
|
|
| |
D8 | Data base error |
|
| |
|
|
|
| |
D9 | No SCSI IC detected |
|
| |
|
|
|
| |
DA | While running the Library Verify Test, | 1. | Check the barcode label on the | |
| the bar code reader read different bar | |||
|
| scratch cartridge, then run the Library Verify Test again. | ||
| code data for the same |
| ||
| 2. | If the error recurs, contact technical support. | ||
| ||||
|
|
| ||
| label. |
|
| |
|
|
|
| |
DB | External cooling fan error (fan motion | 1. | Verify that the indicated fan is operational and not | |
| has stopped). | |||
|
| obstructed. | ||
|
|
| ||
| The subcode indicates which drive sled | 2. If fan is not working, replace the drive sled that is | ||
|
| failing.If the error recurs, contact technical support. | ||
| fan is affected |
| ||
|
|
| ||
| Subcode 01: drive sled #1(bottom) |
|
| |
| Subcode 02: drive sled #2 |
|
| |
|
|
|
| |