Configuration of a 4 Partition System

A four partition system must have four drives. Each partition will contain one drive and one magazine.

Drive 4

Element Address

256

Drive 3

Element Address

256

Drive 2

Element Address

256

Drive 1

Element Address

256

Magazine Magazine

24

Magazine

 

Magazine

1

 

3

 

 

 

Front side

a77ug164

Figure 3-4. Configuration of a Four Partition System

SCSI Element Addressing

Every logical library starts at the first drive slot with the current assigned element start address (default value 256). It will be incremented from the bottom to the top slots for every drive slot. There is one exception to this addressing scheme to accommodate libraries currently in the field. A 4U library which contains only full height drives will continue to have the addresses assignments 256 and 257, thus causing no interruptions to their operation. Drive slots will still be incremented by 1 for each drive slot position.

Note: Exchanging drives with different form factors will result in the library needing to be reconfigured.

4U Unit with only FH drives (1 logical library)

SCSI Element

Slot

 

 

4

257

3

2

256

1

4U Unit with FH and HH drives (1 logical library)

SCSI Element

Slot

258

4

 

3

 

 

 

257

2

 

 

256

1

 

 

Figure 3-5. Examples of SCSI Element Addressing

a77ug165

The SCSI specification does not allow gaps in the SCSI element addressing. Special handling is needed for empty drive slots to fulfill the specification. Also drives which are temporarily removed need to have their address preserved to not confuse the attached host and host application. Generally only drives are reported which are currently physically available or temporarily removed. Empty (unused) slots which are located at the bottom or the top should not be reported, with an