a77ug097
Figure 5-55. The 4U library Service Library: Upgrade Firmware page
Service Library: Reboot
Important: Some options of the Web User Interface take the library OFFLINE. This inactive mode can interfere with
This page is used to perform a library reboot. There is a default time delay when the Web User Interface page refreshes itself. This time should be sufficient to reload the page. However, during a reboot, the connection to the library may be lost. If the connection is lost, the user will have to reload the page manually.
a77ug077
Figure 5-56. Service Library: Reboot page
Import and Export Media during Normal Library Operation
Import Media
Data cartridges can be inserted and taken out of a magazine while the library is in operation. If the library contains an I/O Station, and you wish to import media, follow these steps:
1.Go to Main → Control → Open I/O Station. The I/O Station will unlock itself.
2.Pull out the magazine and insert a data cartridge(s) into the I/O Station. On a 2U library, only 1 cartridge can be inserted at a time. On the 4U library, 3 cartridges can be inserted at one time.
Chapter 5. Operations