Problem | Solution | ||
|
|
| |
Library does not power ON | 1. | Perform “Isolating a Power Supply Problem” on page | |
| |||
|
|
| |
The Operator Control Panel is | 1. | If possible, log on to the Web User Interface and check the error log. (Service | |
blank or frozen | |||
| Library → View Logs) | ||
|
| ||
| 2. Record and note any error code and sub code found. If an error code is found, | ||
|
| look up the error code and try to resolve (see Chapter 8, “Error Codes,” on | |
|
| page | |
| 3. Power cycle the library. | ||
| 4. Download the latest library firmware. | ||
| 5. If the problem still exists, contact technical support. | ||
|
|
| |
Encryption |
|
| |
|
|
| |
Encryption Error: Displayed | 1. | Check the host application to ensure the host application is providing the | |
when the drive detects an error | |||
| correct encryption key. | ||
associated with a encryption |
| ||
| v Refer to the Dell Tape Device Drivers Encryption Support documentation | ||
operation - if the problem |
| ||
| and the Dell LTO Ultrium Tape Drive SCSI Reference documentation for the | ||
occurred while the tape drive |
| ||
| Sense Data returned for an encryption operation. | ||
was writing data to, or reading |
| ||
| v Retry the encryption operation after the host application problems have | ||
data from, tape |
| ||
|
| been resolved. | |
| 2. Check the operation of the tape drive by resetting the drive and running | ||
|
| POST. | |
|
| v Refer to the error code displayed on the SCD if the drive resets and POST | |
|
| fails. | |
|
| v Retry the encryption operation if the drive reset and POST complete without | |
|
| errors. | |
| 3. | Check the media. | |
|
| v Ensure the correct media is being used. Data encryption is supported with | |
|
| LTO Ultrium 4 Data Cartridges only. | |
|
| v Retry the encryption operation with the tape cartridge in another encryption | |
|
| enabled drive. Replace the media if the problem repeats with the same tape | |
|
| cartridge in multiple drives. If the problem occurred while the tape drive | |
|
| was running POST or diagnostics, replace the drive. The error code clears | |
|
| with the first attempted write/read after the encryption key is changed, or | |
|
| when the drive is placed in maintenance mode. | |
|
| posted Check the host application’s error logs, device driver logs, | |
|
| ||
Check the host application’s error logs, device driver logs, tape library error logs, | |||
posted | and tape drive error logs for entries that are related to encryption. See “View | ||
| Logs” on page | ||
| on page | ||
|
|
| |
Chapter 7. Troubleshooting