Chapter 8. Error Codes

If an error occurs during operation of the library, the library stops the current operation and displays an error code on the LCD screen. Unless otherwise noted in Table 8-1 on page 8-2,try to resolve the error by cycling power to the library and retrying the last operation. If the error persists, contact technical support.

Example Error Code

EVENT -6

8D 07

Where:

v-6 indicates the position in sequence list, 0 being the most recent.

v8D 07 indicates the error. (code 8D = sled blocked, ....).

The event log with the library also includes a date stamp for each event. Press

SELECT to display the associated time stamp in the following format:

yy.mm.dd hh:mm:ss:HH

Where:

vyy is the year

vmm is the month

vdd is the current day

vhh is hours

vmm is minutes

vss is seconds

vHH is 1/100 second

The time stamp is set to zero at system start.

A description of each error code and possible solution is provided in Table 8-1 on page 8-2.

Preparing to Resolve an Error Code

1.Record the error information that is displayed on the Operator Control Panel display or Web User Interface screen.

2.If possible, cycle library power and retry operation.

vIf the error reoccurs, refer to Table 8-1 on page 8-2for information on resolving the error.

vIf the error does not reoccur, continue with normal library operation.

Complete the steps in “Preparing to Resolve an Error Code” before completing the User Action listed in Table 8-1 on page 8-2.

8-1

Page 169
Image 169
Dell TL2000 manual Error Codes, Example Error Code, Preparing to Resolve an Error Code