Tape library performance: The library is not efficiently backing up data
1.Check the network bandwidth from the host computer. If you are backing up data over a network, consider comparing to a
2.Ensure that the library and tape drive are on their own SCSI bus and not
3.Ensure that the library is connected to a LVDS SCSI bus and there are no
4.Use an Ultra160 SCSI bus and
Customer Replaceable Units (CRU) and Service Spares
Drive Sled | See “Isolating Drive Sled Problems” on page |
|
|
Power Supply | See “System Status” on page |
| |
|
|
Library Controller Card | See “Isolating a Library Controller Card vs. Accessor Enclosure Problem” on page |
| |
|
|
Library Enclosure (Service | See “Isolating a Library Controller Card vs. Accessor Enclosure Problem” on page |
Spare) | |
|
|
ITDT
Performance Test duration varies
Items affecting the duration of the test are:
vThe level of adapter device driver
vYour adapter model and type
Other Problems
Web User Interface problems | See “Isolating Web User Interface Problems” on page |
|
|
Bar code scanner problems | See “Isolating Accessor Scanner Problems” on page |
|
|
Host Attachment Interface | See “Isolating Host Attachment Interface Problems” on page |
problems |
|
|
|
Need help with a library |
|
password | Contact technical support. |
|
|
Key path diagnostic not | This diagnostic is available with library firmware level greater than 6.xx. Refer to |
working | “Verifying/Updating Firmware” on page |
| on your library. If necessary, visit http://support.dell.com to download the latest |
| levels of firmware for your library. |
|
|
Auto Clean status displayed as | If Auto Clean is enabled and a cleaning cartridge is not present, or if a cleaning |
″Chk Media/Rsvd Slot?″ on the | cartridge is present but not in the reserved slot, Auto Clean status will show ″Chk |
Web User Interface System | Media/Rsvd Slot?″ and Status will show a green check mark and the words |
Status screen. | ″Media Attention.″ |
|
|
Library Recovery Problem Determination
The 2U and 4U library firmware will generally retry failed operations up to three times before posting a failure to complete the operation, or, in some situations, proceeding with an operation that can be completed in an alternative manner. Of course, if the operation is successful within the allotted retry count, the appropriate retry counter is updated and recorded in the retry log and the next library operation will commence.
For example, failure to pick or place a cartridge from or to a designated cell or drive location after exhausting the retry count will result in a failed operation with the appropriate error code. However, failure to detect a particular cell location by sensing the prism fiducial located on the cell shelf because it is missing or damaged will eventually result in the cell location being located by the gripper, bar