Inserting the Cleaning Cartridge

See the Note below for 4U libraries with a Dedicated Cleaning Slot (DCS).

The following criteria must be followed for Auto Clean to function:

1.The Auto Clean function must be configured Onor Enabled.

vOperator Control Panel: Configure->Library Settings->Enabled

vWeb User Interface: Configure Library->General->Auto Clean->checkmark

Note: Earlier versions of the 4U library contained a Dedicated Cleaning Slot (DCS). This DCS can be retained and is supported by future library firmware updates. However, library firmware later than 3.90 will allow removal of the DCS, thus enabling this slot to be used as a storage slot. Once the DCS is removed, the Auto Clean cleaning cartridge slot must be configured as described below. If the DCS has been removed, it can only be reinstated by restoring factory default settings. To remove the DCS, perform the following procedure using the Operator Control Panel (OCP): OCP->Configure->LibrarySettings->General- >Remove DCS->No/Yes->Save.

2.A storage slot must be reserved (Res or RSVD).

vReserving a slot is accomplished by reducing the Active Slot count in any particular logical library. A reserved slot (or slots) is always the last slot in the last magazine of any particular logical library. A cleaning cartridge that is in a reserved slot is available to any logical library drive even if the reserved slot is not in that particular logical library. If the library contains multiple logical libraries, typically, the last logical library is chosen to be the reserved slot containing the cleaning cartridge. As with a library with a single logical library, this slot is the last physical slot in the library (top right magazine, uppermost rear slot).

3.A cleaning cartridge (CLNxxxLx) must be placed or moved to a reserved slot.

vA cleaning cartridge must be replaced after 50 uses. Click on the Web User Interface, Monitor Library->Inventory .

vFind the magazine that contains the cleaning cartridge.

vClick on the (+) located under that magazine presentation to expand the detail of resident cartridges.

vObserve the cleaning cartridge location displayed. The number of Media Loads represent how many times the cleaning cartridge has been used. The number 50, minus that Media Load number represents the number of uses left.

4.To install a cleaning cartridge in the 2U or 4U library:

a. Use the Operator Control Panel: Control Move Cartridge or the Web User Interface: Manage Library Move Media to insert the cleaning cartridge into the reserved slot or the DCS (if one exists, 4U only).

b. An alternate method is to use the Release Magazine option: v Operator Control Panel: Control Magazine (Left/Right)

vWeb User Interface: Manage Library Release Magazines (Left/Right)

c.Place a cleaning cartridge into the reserved slot or the DCS (if one exists, 4U only).

Note: A user has the option to perform manual cleaning by navigating in the RMU to Service Clean Drive. In units with more than one drive to be

4-34Dell PowerVault TL2000 Tape Library and TL4000 Tape Library User's Guide

Page 84
Image 84
Dell TL2000 manual Inserting the Cleaning Cartridge