Table
Error Code | Description | User Action |
|
|
|
8E | Cannot find gripper block within the |
|
| expected range |
|
|
|
|
8F | Cannot find slider block within the |
|
| expected range |
|
|
|
|
90 | Cannot find elevator block within the |
|
| expected range |
|
|
|
|
91 | Cannot find rotation block within the |
|
| expected range |
|
|
|
|
92 | Cannot find sled block within the |
|
| expected range |
|
|
|
|
93 | Gripper outside range, |
|
| Gripper has reached a position beyond |
|
| the expected range |
|
|
|
|
94 | Slider outside range, |
|
| Slider has reached a position beyond the |
|
| expected range |
|
|
|
|
95 | Elevator outside range, |
|
| Elevator has reached a position beyond | 1. Run the Library Verify Test, then retry the operation. |
| 2. If the error recurs, contact technical support. | |
| the expected range | |
|
|
|
96 | Rotation outside range, |
|
| Rotation has reached a position beyond |
|
| the expected range |
|
|
|
|
97 | Sled outside range, |
|
| Sled has reached a position beyond the |
|
| expected range |
|
|
|
|
98 | Cartridge present sensor not found |
|
|
|
|
99 | Slider home sensor not found |
|
|
|
|
9A | Rotation home sensor not found |
|
|
|
|
9B | Sled position sensor not found |
|
|
|
|
9C | Gripper range out of specification |
|
|
|
|
9D | Slider range out of specification |
|
|
|
|
9E | Elevator range out of specification |
|
|
|
|
9F | Rotation range out of specification |
|
|
|
|
A0 | Sled range out of specification |
|
|
|
|
A1 | Open I/O Station (Import/Export |
|
| Element) failed |
|
|
|
|
B0 | Robotic controller response timeout. A |
|
| command did not complete in the | Contact technical support. |
| required amount of time. | |
|
| |
|
|
|
B1 | NACK (not acknowledged) received |
|
| from robotic controller |
|
|
|
|
B2 | Accessor controller communication failed |
|
|
|
|
Chapter 8. Error Codes