TapeAlert Flags Supported by the Drive

Table B-1. TapeAlert Flags Supported by the Ultrium Tape Drive

Flag

 

 

 

Number

Flag

Description

Action Required

 

 

 

 

3

Hard error

Set for any unrecoverable read, write,

See the Action Required column for

 

 

or positioning error. (This flag is set in

Flag Number 4, 5, or 6 in this table.

 

 

conjunction with flags 4, 5, or 6.)

 

 

 

 

 

4

Media

Set for any unrecoverable read, write,

Replace the tape cartridge.

 

 

or positioning error that is due to a

 

 

 

faulty tape cartridge.

 

 

 

 

 

5

Read failure

Set for any unrecoverable read error

If Flag 4 is also set, the cartridge is

 

 

where isolation is uncertain and

defective. Replace the tape

 

 

failure could be due to a faulty tape

cartridge.

 

 

cartridge or to faulty drive hardware.

 

 

 

 

 

6

Write failure

Set for any unrecoverable write or

If Flag Number 9 is also set, make

 

 

positioning error where isolation is

sure that the write-protect switch is

 

 

uncertain and failure could be due to

set so that data can be written to

 

 

a faulty tape cartridge or to faulty

the tape (see “Write-Protect Switch”

 

 

drive hardware.

on page 6-5)). If Flag Number 4 is

 

 

 

also set, the cartridge is defective.

 

 

 

Replace the tape cartridge.

 

 

 

 

7

Media life

Set when the tape cartridge reaches its

1. Copy the data to another tape

 

 

end of life (EOL).

cartridge. .

 

 

 

 

 

 

2. Discard the old (EOL) tape.

 

 

 

 

8

Not data grade

Set when the cartridge is not

Replace the tape with a data-grade

 

 

data-grade. Any data that you write

tape.

 

 

to the tape is at risk.

 

 

 

 

 

9

Write protect

Set when the tape drive detects that

Ensure that the cartridge’s

 

 

the tape cartridge is write-protected.

write-protect switch is set so that

 

 

 

the tape drive can write data to the

 

 

 

tape (see “Write-Protect Switch” on

 

 

 

page 6-5).

 

 

 

 

10

No removal

Set when the tape drive receives an

Refer to the documentation for your

 

 

UNLOAD command after the server

server’s operating system.

 

 

prevented the tape cartridge from

 

 

 

being removed.

 

 

 

 

 

11

Cleaning media

Set when you load a cleaning

No action required.

 

 

cartridge into the drive.

 

 

 

 

 

12

Unsupported format

Set when you load an unsupported

Use a supported tape cartridge.

 

 

cartridge type into the drive or when

 

 

 

the cartridge format has been

 

 

 

corrupted.

 

 

 

 

 

15

Cartridge memory chip

Set when a cartridge memory (CM)

Replace the tape cartridge.

 

failure

failure is detected on the loaded tape

 

 

 

cartridge.

 

 

 

 

 

16

Forced eject

Set when you manually unload the

No action required.

 

 

tape cartridge while the drive was

 

 

 

reading or writing.

 

 

 

 

 

17

Media loaded is

Set when a cartridge marked as read

No action required.

 

Read-only format

only is loaded into the drive. The flag

 

 

 

is cleared when the cartridge is

 

 

 

ejected.

 

 

 

 

 