THERMAL CONSIDERATIONS

Thermal management is an important part of the system design. To ensure proper, reliable operation, sufficient cooling of the power module is needed over the entire temperature range of the module. Convection cooling is usually the dominant mode of heat transfer.

Hence, the choice of equipment to characterize the thermal performance of the power module is a wind tunnel.

Thermal Testing Setup

Delta’s DC/DC power modules are characterized in heated vertical wind tunnels that simulate the thermal environments encountered in most electronics equipment. This type of equipment commonly uses vertically mounted circuit cards in cabinet racks in which the power modules are mounted.

The following figure shows the wind tunnel characterization setup. The power module is mounted on a test PWB and is vertically positioned within the wind tunnel. The space between the neighboring PWB and the top of the power module is constantly kept at 6.35mm (0.25’’).

Thermal Derating

Heat can be removed by increasing airflow over the module. The hottest point temperature of the module is 129. To enhance system reliability; the power module should always be operated below the maximum operating temperature. If the temperature exceeds the maximum module temperature, reliability of the unit may be affected.

THERMAL CURVES

Figure 21: Case temperature measurement location. Pin locations are for reference only.

The allowed maximum hot spot temperature is defined at 129

E48SH3R330(Standard) Output Current vs. Ambient Temperature and Air Velocity

FACING PWB

AIR VELOCITY

AND AMBIENT

TEMPERATURE

MEASURED BELOW

THE MODULE

PWB

MODULE

50.8 (2.0”)

AIR FLOW

12.7 (0.5”)

Output Current(A)

@Vin = 48V (Transverse Orientation)

30

 

 

Natural

 

Convection

25

 

 

100LFM

20

200LFM

300LFM

15

400LFM

10

5

0

25

30

35

40

45

50

55

60

65

70

75

80

85

 

 

 

 

 

 

 

 

 

 

Ambient Temperature ()

Figure 22: Output current vs. ambient temperature and air velocity @ Vin=48V (Transverse Orientation)

Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches)

Figure 20: Wind tunnel test setup

E48SH3R330_02162007

10

Image 10
Contents Features Technical Specifications ParameterElectrical Characteristics Curves Typical full load input characteristics at room temperatureFor Negative Remote On/Off Logic Electrical Characteristics Curves Input reflected ripple current, is, through a 12µH Design Considerations Input Source ImpedanceFeatures Descriptions Features Descriptions CON Output Voltage Adjustment TrimThermal Curves Thermal Testing SetupThermal Considerations Thermal DeratingE48SH3R33002162007 Leaded Sn/Pb Process Recommend TEMP. Profile Lead Free SAC Process Recommend TEMP. ProfileMechanical Drawing Pin No Name FunctionMechanical Drawing with Heatspreader Part Numbering System Model List