6)SW3 is used for the trim-down or trim-up setting of the Output Voltage. For IPM, if the converter requires a trim up, set SW3 to the Trim-up position. If the converter requires a trim down, set SW3 to the Trim-down position. For normal operating, turn off the SW3.

7)SW4 and SW5 are used for the Output Voltage Set-Point Adjustment by external resistors. For IPM12C0A0R04A, if the converter requires a trim-up to 5V, set the SW4_1 to ON position and SW3 to trim-up position. If the converter requires a trim-down to 0.8V, set the SW5_8 to ON position and SW3 to trim-down position.

8)For constant output voltage module, if the converter requires a trim-up, set the SW4_2 to ON position and SW3 to trim-up position. If the converter requires a trim-down, set the SW5_8 to ON position and SW3 to trim-down position. Please refer to the Function Tables below for the setting details.

SW4 Function Table

Subdivide switch NO.

For adjustable output

 

module

SW4_1

5.0V setting

SW4_2

3.3V setting

SW4_3

2.5V setting

SW4_4

1.8V setting

SW4_5

1.5V setting

SW4_6

1.2V setting

SW4_7

1.0V setting

SW4_8

0.95V setting

For constant output

module

5.0V trim up

3.3V trim up

2.5V trim up

1.8V trim up

1.5V trim up

1.2V trim up

1.0V trim up

0.9V trim up

Note: Settings of SW4_1 and SW4_7 are for IPM12C series only

SW5 Function Table

Subdivide switch NO.

For adjustable output

 

module

SW5_1

-

SW5_2

-

SW5_3

-

SW5_4

-

SW5_5

-

SW5_6

-

SW5_7

-

SW5_8

0.80V setting

For constant output

module

5.0V trim down

3.3V trim down

2.5V trim down

1.8V trim down

1.5V trim down

1.2V trim down

1.0V trim down

0.9V trim down

5

Image 5
Contents Relevant Documentation IPM- C Series POL convertersPurpose Equipment Set-Up and Description Equipment RequiredThermal Management of the Converter Test Set-Up Tests PerformedSW4 Function Table Tests and Evaluation Initial Power UpTest No Load Input Current TestOutput Ripple Output Characteristics Line RegulationLoad Regulation For IPM12C series Output Voltage Set-Point Adjustment Range Trim− 0.187 kΩ For IPM12C series Turn-On Transient Time Dynamic Characteristics Output Voltage DeviationTest Turn on the module by using the Enable on/off Test Turn on the module by using the external switchVin=5.5V Vin=5.0V Vin=4.0V Appendix A- Evaluation Board Schematic Appendix B Evaluation Board Layout Top View Appendix C Evaluation Board Layout Bottom View