6. Transmitter Burst Mode Timing Characteristics
Parameter | Symbol | Min. | Typ. | Max. | Unit | Note |
BiasCNT Enable Duration |
| 1 |
|
| us |
|
Interval of BiasCNT Signal |
| 0.112 |
| 1000000 | us |
|
BiasCNT
BiasCNT Enable Duration
Interval of BiasCNT Signal
VccT | BiasCNT | Data Input | Optical Output | |
VccT < 3.1V | X | X | OFF | |
VccT > 3.1V | Low | X | OFF | |
High | Floating | Other | ||
| ||||
|
| Present | Laser bias and modulation signal output |
X = Don’t care
Other = Less than +7.5dBm (peak)
High = Logic high level, Low = logic low level
Floating = No Data Input, Present = Data Input,
OFF = Optical Power is less than
BiasCNT
Data Input
Optical Output | Within 15% of steady state |
|
| Ton | Toff |
H
L
7. Digital Diagnostic Monitor Accuracy
| Parameter | Accuracy | Unit | Calibration | Note |
|
| Transceiver Internal Temperature | ± 3℃ | ℃ | Internal |
| |
| Power Supply Internal Voltage | ± 3% | V | Internal | VCC=3.3V±5% |
|
| TX Bias Current | ± 10% | mA | Internal | Specified by nominal bias value |
|
| TX Optical Power | ± 3dB | dBm | Internal | Not support in burst ONU |
|
| RX Optical Power | ± 3dB | dBm | Internal |
| |
| Note. Temperature and Voltage is measured internal to the transceiver. |
|
| |||
|
|
| 5 |
| Revision: S3 | |
|
|
|
|
| 12/20/2007 | |
DELTA ELECTRONICS, INC. |
|
|
| www.deltaww.com |