Delta Electronics LCP-1250B4QDRx specifications Delta ELECTRONICS, INC

Page 5

Notes:

1)TX Fault is an open collector/drain output, which should be pulled up with a 4.7K – 10KΩ resistor on the host board. Pull up voltage between 2.0V and VccT, R+0.3V. When high, output indicates a laser fault of some kind. Low indicates normal operation. In the low state, the output will be pulled to < 0.8V.

2)TX disable is an input that is used to shut down the transmitter optical output. It is pulled up within the module with a 4.7 – 10 K Ω resistor. Its states are:

Low (0 – 0.8V):

Transmitter on

(>0.8, < 2.0V):

Undefined

High (2.0 – 3.465V):

Transmitter Disabled

Open:

Transmitter Disabled

3)Mod-Def 0,1,2. These are the module definition pins. They should be pulled up with a 4.7K – 10KΩresistor on the host board. The pull-up voltage shall be VccT or VccR (see Section IV for further details). Mod-Def 0 is grounded by the module to indicate that the module is present Mod-Def 1 is the clock line of two wire serial interface for serial ID Mod-Def 2 is the data line of two wire serial interface for serial ID

4)LOS (Loss of Signal) is an open collector/drain output, which should be pulled up with a 4.7K – 10KΩ resistor. Pull up voltage between 2.0V and VccT, R+0.3V. When high, this output indicates the received optical power is below the worst-case receiver sensitivity (as defined by the standard in use). Low indicates normal operation. In the low state, the output will be pulled to < 0.8V.

5)VeeR and VeeT may be internally connected within the SFP module.

6)RD-/+: These are the differential receiver outputs. They are AC coupled 100Ω differential lines which should be terminated with 100Ω (differential) at the user SERDES. The AC coupling is done inside the module and is thus not required on the host board. The voltage swing on these lines will be between 370 and 2000 mV differential (185 – 1000 mV single ended) when properly terminated.

7)VccR and VccT are the receiver and transmitter power supplies. They are defined as 3.3V ±5% at the SFP connector pin. Maximum supply current is 300mA. Recommended host board power supply filtering is shown below. Inductors with DC resistance of less than 1 ohm should be used in order to maintain the required voltage at the SFP input pin with 3.3V supply voltage. When the recommended supply-filtering network is used, hot plugging of the SFP transceiver module will result in an inrush current of no more than 30mA greater than the steady state value. VccR and VccT may be internally connected within the SFP transceiver module.

8)TD-/+: These are the differential transmitter inputs. They are AC-coupled, differential lines with 100Ω differential termination inside the module. The AC coupling is done inside the module and is thus not required on the host board. The inputs will accept differential swings of 500 – 2400 mV (250 – 1200 mV single-ended), though it is recommended that values between 500 and 1200 mV differential (250 – 600 mV single-ended) be used for best EMI performance.

5

2008/1/23

 

Rev. 6G

DELTA ELECTRONICS, INC.

www.deltaww.com

Image 5
Contents Performance DescriptionApplications Recommended Operating Conditions Electrical CharacteristicsAbsolute Maximum Ratings Mask of the eye diagram for the optical transmit signal Optical CharacteristicsMOD-DEF2 Delta ELECTRONICS, INC PLD / PAL Package Outline Drawing SFP timing parameters for SFP management Parameter Symbol Min Max UnitEnhanced Digital Diagnostic Interface Eeprom Serial ID Memory Contents 2-Wire Address A0h Address Name Value Dec Unit Bytes Digital Diagnostic Monitoring InterfaceState/ Control Bits Optional Set of Alarm and WarningOrdering information for SFP modules X1 TemperatureRegulatory Compliance

LCP-1250B4QDRx specifications

Delta Electronics, a global leader in power and thermal management solutions, has introduced the LCP-1250B4QDRx, a sophisticated liquid cooling unit designed to enhance the efficiency and sustainability of data centers. This advanced cooling solution is particularly appealing for high-density environments that require effective temperature control to maintain optimal operating conditions for critical IT equipment.

One of the standout features of the LCP-1250B4QDRx is its impressive cooling capacity of up to 1250 kW. This makes it an ideal choice for modern data centers with high heat loads, allowing operators to scale their facilities without compromising on cooling efficiency. The unit employs a high-efficiency liquid-to-air heat exchanger, which maximizes heat transfer while minimizing energy consumption, thereby contributing to a reduced overall carbon footprint.

The LCP-1250B4QDRx utilizes Delta's proprietary digital control technology, which allows for precise monitoring and management of cooling performance. This feature not only enables real-time adjustments based on varying thermal loads but also facilitates predictive maintenance, ensuring that the system operates optimally throughout its lifecycle. The integration of smart sensors and IoT connectivity further enhances the operational intelligence of the unit, allowing data center managers to access real-time data for improved decision-making.

In terms of design, the LCP-1250B4QDRx boasts a modular architecture that supports seamless integration into existing infrastructures. Its flexibility allows for easy installation and scalability, accommodating the evolving needs of data centers over time. The unit is also engineered with user-friendly interfaces, making it accessible for operators to manage and monitor system performance effortlessly.

Another significant characteristic of the LCP-1250B4QDRx is its quiet operation. Designed with noise reduction in mind, this cooling solution minimizes acoustic impact, creating a more conducive working environment for personnel while satisfying regulatory noise requirements.

In conclusion, Delta Electronics' LCP-1250B4QDRx represents a leap forward in liquid cooling technology for data centers. With its high cooling capacity, efficient design, intelligent monitoring capabilities, and quiet operation, it stands out as a reliable choice for organizations looking to enhance their facility’s cooling capabilities while prioritizing energy efficiency and sustainability. As data centers continue to grow in complexity and demand, the LCP-1250B4QDRx is positioned to meet the challenges of the future.