Delta Electronics LCP-1250B4QDRx Absolute Maximum Ratings, Recommended Operating Conditions

Page 2

Absolute Maximum Ratings

Parameter

Symbol

Min.

Typ.

Max.

Unit

Note

Storage Temperature

Ts

-40

 

85

ºC

 

Supply Voltage

VCC

0

 

5

V

 

Recommended Operating Conditions

 

Parameter

Symbol

Min.

Typ.

Max.

Unit

Note

 

Case Operating Temperature

TC

-5

 

70

ºC

1

 

Supply Voltage

VCC

3.135

 

3.465

V

 

 

Relative Humidity (non condensation)

-

5

 

85

%

 

 

Note 1: See order information

 

 

 

 

 

 

Electrical Characteristics

 

 

 

 

 

 

(VCC=3.3V ± 5%)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Symbol

Min.

Typ.

Max.

Unit

Note

 

Total Supply Current

ICCT

 

 

300

mA

 

 

Transmitter

 

 

 

 

 

 

 

Transmitter Differential Input Voltage

VDT

0.5

 

2.4

V

1

 

Transmitter Disable Input-High

VDISH

2

 

VCC+0.3

V

 

 

Transmitter Disable Input-Low

VDISL

0

 

0.8

V

 

 

Transmitter Fault Pull up Resistor

RTX_FAULT

4.7

 

10

kΩ

2

 

Transmitter Fault Output-High

VTXFH

2

 

VCC+0.3

V

2

 

Transmitter Fault Output-Low

VTXFL

0

 

0.8

V

2

 

Receiver

 

 

 

 

 

 

 

Receiver Differential Output Voltage

VDR

0.35

 

2

V

3

 

Receiver LOS Load

RRXLOS

4.7

 

10

kΩ

2

 

LOS Output Voltage-High

VLOSH

2

 

VCC+0.3

V

2

 

LOS Output Voltage-Low

VLOSL

0

 

0.8

V

2

 

Output Data Rise/Fall Time

tr / tf

 

220

 

psec

4

Notes:

1.Internally AC coupled and terminated to 100Ohm differential load.

2.Pull up to VCC on host Board

3.Internally AC coupled, but requires a 100Ohm differential termination at or internal to Serializer/ Deserializer.

4.These are 20%~80% values

2

2008/1/23

 

Rev. 6G

DELTA ELECTRONICS, INC.

www.deltaww.com

Image 2
Contents Performance DescriptionApplications Recommended Operating Conditions Electrical CharacteristicsAbsolute Maximum Ratings Optical Characteristics Mask of the eye diagram for the optical transmit signalMOD-DEF2 Delta ELECTRONICS, INC PLD / PAL Package Outline Drawing Parameter Symbol Min Max Unit SFP timing parameters for SFP managementEnhanced Digital Diagnostic Interface Eeprom Serial ID Memory Contents 2-Wire Address A0h Digital Diagnostic Monitoring Interface Address Name Value Dec Unit BytesOptional Set of Alarm and Warning State/ Control BitsOrdering information for SFP modules X1 TemperatureRegulatory Compliance

LCP-1250B4QDRx specifications

Delta Electronics, a global leader in power and thermal management solutions, has introduced the LCP-1250B4QDRx, a sophisticated liquid cooling unit designed to enhance the efficiency and sustainability of data centers. This advanced cooling solution is particularly appealing for high-density environments that require effective temperature control to maintain optimal operating conditions for critical IT equipment.

One of the standout features of the LCP-1250B4QDRx is its impressive cooling capacity of up to 1250 kW. This makes it an ideal choice for modern data centers with high heat loads, allowing operators to scale their facilities without compromising on cooling efficiency. The unit employs a high-efficiency liquid-to-air heat exchanger, which maximizes heat transfer while minimizing energy consumption, thereby contributing to a reduced overall carbon footprint.

The LCP-1250B4QDRx utilizes Delta's proprietary digital control technology, which allows for precise monitoring and management of cooling performance. This feature not only enables real-time adjustments based on varying thermal loads but also facilitates predictive maintenance, ensuring that the system operates optimally throughout its lifecycle. The integration of smart sensors and IoT connectivity further enhances the operational intelligence of the unit, allowing data center managers to access real-time data for improved decision-making.

In terms of design, the LCP-1250B4QDRx boasts a modular architecture that supports seamless integration into existing infrastructures. Its flexibility allows for easy installation and scalability, accommodating the evolving needs of data centers over time. The unit is also engineered with user-friendly interfaces, making it accessible for operators to manage and monitor system performance effortlessly.

Another significant characteristic of the LCP-1250B4QDRx is its quiet operation. Designed with noise reduction in mind, this cooling solution minimizes acoustic impact, creating a more conducive working environment for personnel while satisfying regulatory noise requirements.

In conclusion, Delta Electronics' LCP-1250B4QDRx represents a leap forward in liquid cooling technology for data centers. With its high cooling capacity, efficient design, intelligent monitoring capabilities, and quiet operation, it stands out as a reliable choice for organizations looking to enhance their facility’s cooling capabilities while prioritizing energy efficiency and sustainability. As data centers continue to grow in complexity and demand, the LCP-1250B4QDRx is positioned to meet the challenges of the future.