CY7C1370DV25
CY7C1372DV25
TAP AC Switching Characteristics Over the Operating Range[9, 10]
Parameter | Description | Min. | Max. | Unit |
Clock |
|
|
|
|
tTCYC | TCK Clock Cycle Time | 50 |
| ns |
tTF | TCK Clock Frequency |
| 20 | MHz |
tTH | TCK Clock HIGH time | 20 |
| ns |
tTL | TCK Clock LOW time | 20 |
| ns |
Output Times |
|
|
| |
|
|
|
|
|
tTDOV | TCK Clock LOW to TDO Valid |
| 10 | ns |
tTDOX | TCK Clock LOW to TDO Invalid | 0 |
| ns |
|
|
|
| |
|
|
|
|
|
tTMSS | TMS | 5 |
| ns |
tTDIS | TDI | 5 |
| ns |
tCS | Capture | 5 |
| ns |
Hold Times |
|
|
|
|
tTMSH | TMS Hold after TCK Clock Rise | 5 |
| ns |
tTDIH | TDI Hold after Clock Rise | 5 |
| ns |
tCH | Capture Hold after Clock Rise | 5 |
| ns |
Notes:
9.tCS and tCH refer to the
10. Test conditions are specified using the load in TAP AC test Conditions. tR/tF = 1 ns.
Document #: | Page 13 of 27 |
[+] Feedback