Delta Electronics S48SP manual Features Descriptions, Over-Current Protection, Remote On/Off

Page 8

FEATURES DESCRIPTIONS

Over-Current Protection

The modules include an internal output over-current protection circuit, which will endure current limiting for an unlimited duration during output overload. If the output current exceeds the OCP set point, the modules will automatically shut down, and enter hiccup mode or latch mode, which is optional.

For hiccup mode, the module will try to restart after shutdown. If the overload condition still exists, the module will shut down again. This restart trial will continue until the overload condition is corrected.

For latch mode, the module will latch off once it shutdown. The latch is reset by either cycling the input power or by toggling the on/off signal for one second.

Remote On/Off

The remote on/off feature on the module can be either negative or positive logic. Negative logic turns the module on during a logic low and off during a logic high. Positive logic turns the modules on during a logic high and off during a logic low.

Remote on/off can be controlled by an external switch between the on/off terminal and the Vi(-) terminal. The switch can be an open collector or open drain.

For negative logic if the remote on/off feature is not used, please short the on/off pin to Vi(-). For positive logic if the remote on/off feature is not used, please leave the on/off pin floating.

Over-Voltage Protection

The modules include an internal output over-voltage protection circuit, which monitors the voltage on the output terminals. If this voltage exceeds the over-voltage set point, the module will shut down, and enter in hiccup mode or latch mode, which is optional.

For hiccup mode, the module will try to restart after shutdown. If the overload condition still exists, the module will shut down again. This restart trial will continue until the overload condition is corrected.

ON/OFF

Vi(-)

Vi(+)

Vo(-)

Trim

Vo(+)

R

Load

For latch mode, the module will latch off once it shutdown. The latch is reset by either cycling the input power or by toggling the on/off signal for one second.

Over-Temperature Protection

The over-temperature protection consists of circuitry that provides protection from thermal damage. If the temperature exceeds the over-temperature threshold the module will shut down, and enter in hiccup mode or latch mode, which is optional.

For hiccup mode, the module will try to restart after shutdown. If the overload condition still exists, the module will shut down again. This restart trial will continue until the overload condition is corrected.

For latch mode, the module will latch off once it shutdown. The latch is reset by either cycling the input power or by toggling the on/off signal for one second.

DS_S48SP05007_05222008

Figure 16: Remote on/off implementation

8

Image 8
Contents Features Technical Specifications ParameterElectrical Characteristics Curves Typical full load input characteristics at room temperatureFor Negative Remote On/Off Logic For Positive Remote On/Off LogicElectrical Characteristics Curves Output voltage noise and ripple measurement test setup Safety Considerations Soldering and Cleaning ConsiderationsDesign Considerations Input Source ImpedanceFeatures Descriptions Over-Temperature ProtectionOver-Current Protection Remote On/OffFeatures Descriptions CON Output Voltage AdjustmentThermal Considerations Thermal CurvesPick and Place Location Recommended PAD Layout SMDLeaded Sn/Pb Process Recommend TEMP. Profile Lead Free SAC Process Recommend TEMP. ProfileMechanical Drawing Surface-mount module Through-Hole modulePart Numbering System Model List