8. BATTERY PACK REMOVAL

This procedure provides instructions for removing the battery pack. Refer to Figure 7 during this proce- dure.

1.Place the Site Master face up on a work sur- face.

2.Remove the four corner rubber bumpers (1).

3.Remove the four screws (PN 900-811) (2).

4.While holding the two halves of the Site Mas- ter together, turn it over and set it face down on the work surface.

CAUTION

5.Remove the bottom half (5) and fold it over to lay upside down on the work surface.

6.Disconnect the red/black cable of the battery pack from J6 (6) of the Main RF PCB assem- bly (3).

7.Remove the four screws (7) holding the bat- tery bracket (8) in place and lift the bracket clear.

8.Remove the battery assembly (9).

In the next step, the Main RF PCB assembly (3) and test port panel (4) must stay with the front panel.

5

9

Detail A

Raised

Wedge

8

N274

Power

External

Serial

Charging

Battery

DCmA)

(850

15V-5.

 

12

 

 

7 (4 Places)

6

3

 

 

10

 

 

Ports

Test

2 (4 Places)

4

Figure 7. Site Master Battery Removal

Det

RF

1 (4 Places)

Site Master S820A MM

7

Image 7
Contents Description Introduction Performance VerificationFrequency Accuracy ProcedureReturn Loss Verification 560-7N50B RF Detector Power Monitor VerificationTermination Verification XXA Precision Return Loss Test SetupExample of a Good Connection Site Master Battery Removal Battery Pack RemovalBattery Pack Replacement Battery Disposal LCD Replacement KEY PAD Membrane ReplacementMain PCB and RF Module Assembly Replacement Replaceable parts for the Site Master are listed in Table Replaceable PartsRF Measurement Chart Return Loss Verification Worksheet Anritsu Service Centers