Second Controller Option
Verifying the Controller Operating Parameters
For optimal
■Host I/O channel 0 for Controller 1 (top) to Active
■Host I/O channel 1 for Controller 1 to Passive
■Channel 0 Target ID for Controller 1 to 0
■Channel 1 Target ID for Controller 2 to 1
NOTE: It is allowable to configure the host I/O and target IDs as follows:
Controller 1 (top) may be set to “ Passive” while host I/O channel 1 for Controller 1 is set to “ Active” . As long as each host channel value and channel target ID value is unique, the system is correctly configured for Active/Active mode.
1.Select the Environment tab from the Controller Properties window.
2.Ensure the cabinet and UPS settings are set to normal.
3.Select the Cache tab from the Controller Properties window. The SIMMs parameters must be identical between controllers.
4.Select OK. The system is now ready for