Compaq EK-SMCPO-UG. C01 manual Maintenance

Page 10

x RAID Array 3000 Pedestal Storage Subsystem Hardware User's Guide

Chapter 2: RAID Array Controller

nController Overview

nController Features

nController Reset and LED Indicators

nFlexible RAID Set Configuration

nPerformance Enhancements

nRAID Levels Supported

nRedundant Operation

nEnvironmental

Chapter 3: Maintenance

nPedestal Status and Power LEDs

nSBB Status LEDs

nController LEDs

nEMU Error Reporting

nReplacing Components (FRUs)

nDifferential/Wide UltraSCSI Bus

nReplacing the Controller Memory Cache Modules

Chapter 4: RAID Array Controller

nProduct Description

nExpansion Pedestal Cabinet

nExpansion Pedestal Components

nReconfiguring Base Pedestal UltraSCSI Bus

Chapter 5: Second Controller Option

nSecond Controller Option Kit

nInstalling the Upgrade

nConfiguring a Dual Controller Installation for a Single Serial Port

Image 10
Contents Compaq StorageWorks Page Contents RAID Array Controller List of Figures RAID 0 write List of Tables Page About This Guide Maintenance Related Documents Text Conventions Symbols in Text This is a test Rack Stability Compaq Website Product Overview Product DescriptionRAID Array 3000 pedestal enclosure drives optional Compaq Part No RA3000 pedestal subsystem with one controller, 230Pedestal Features Pedestal CabinetPedestal front panel major components StorageWorks Building Blocks SBBs Pedestal ComponentsRAID Array Controller Pedestal Power Supplies UPSEnvironmental Monitor Unit EMU EMU circuit board locationShows the Pedestal rear panel components UltraSCSI bus port and default Scsi ID assignments UltraSCSI BusesUltraSCSI bus configuration switch Connecting the Pedestal to a Host System Single Host, Single Adapter Cabling ItemÂDescriptionSingle Host, Dual Adapter/Dual Controller Cabling DescriptionHost System Dual Host, Single Adapter/Single Controller Cabling Specifications Pedestal Technical SpecificationsDimension Pedestal Physical and Power SpecificationPhysical Specifications Power SpecificationsRAID Array Controller Controller OverviewPage Controller Features Bridging the gap between the host and the pedestalUnits created from storagesets, partitions, and disk drives Controller Specifications SpecificationsController Specifications Environmental Controller Reset and LED IndicatorsLED/Reset Switch Interface NameFlexible RAID Set Configuration Shows the front panel of the controllerPerformance Enhancements Custom ComponentsEfficient Write and Read Algorithms Write-Back CachingWrite Gathering Write On TopPedestal RAID Set Restrictions RAID Levels SupportedRAID Levels Supported Max. No. * of DrivesRAID Shows a diagram of a RAID 0 write Diagram of a RAID 1 write RAID 0+1Drives Selected RAID 0+1 ExampleFunction Diagram of a RAID 4 write Page Diagram of a RAID 5 write Redundant Operation Just a Bunch of Drives JbodMessage Passing EnvironmentalInitialization FailoverCondition Backup Power ManagementResponse to Various AC Power Conditions ResponseAcceptable System Voltage Levels Voltage MonitoringSystem Voltage Termination VoltageAcceptable External Temperature Levels Temperature MonitoringExternal Temperature Supply VoltageBoard Temperature Acceptable Board Temperature LevelsPage Maintenance Pedestal Status and Power LEDs SBB Status LEDs Shows the Pedestal status LEDsController LEDs Activity LED Fault LED IndicationDisk Drive SBB Status LEDs EMU Error Reporting EMU Error ConditionsReplacing Components FRUs Removing the Pedestal Door Replacing an SBBReplacing an SBB Replacing a Power Supply Replacing a power supplyReplacing the RAID Array Controller Removing the controller from the pedestalReplacing the EMU Board Tools requiredRemove standoffs from UPS and external fault connectors Differential/Wide UltraSCSI Bus Replacing the UPSAssigned Slot Device Addresses in the Pedestal Reconfiguring the Scsi BusScsi Bus Length and External Cables Rate Bus LengthMaintenance Shows how to remove the screw and panel Close the side panels and replace the cover screw Replacing the Controller Memory Cache Modules 11. Remove controller12 shows how to release the locking clips 14. Install replacement Simm Expansion Pedestal Option Expansion Pedestal Cabinet Shows the Expansion PedestalExpansion Pedestal Option Shows the rear panel power supplies Expansion Pedestal ComponentsEMU Reconfiguring Base Pedestal UltraSCSI Bus Remove the side cover from the base pedestal Figure Disconnect Scsi cable Connect Scsi jumper Remove connector knockout plate 10. Connect Scsi cable Set the bus configuration switch to 7 Figures 4-11 13. Reconfigured Scsi bus addresses 14. Connect Scsi cable between pedestals 15. Power cable connections 16. Transfer drives from base to expansion pedestal Second Controller Option Second Controller Option Kit Second controller pedestal slot locationInstalling the Upgrade Saving Existing ConfigurationUpdating Firmware Using Swcc Updating FirmwareUpdating Firmware Using Serial Interface Firmware update dialog boxShutting Down the RA3000 Installing Two SIMMs into Second Controller Insert Simm into connectorReplacing Existing Controller Remove controller from top slotRestoring the Configuration Restoring configuration to new controller10. Restored configuration example Updating Firmware on Second ControllerInstalling Original Controller Configuring the RA3000 for the Active Mode Operation Configuring the Dual Controllers Connecting to Your Dual Controller Storage System Verifying the Controller Operating Parameters