Compaq EK-SMCPO-UG. C01 manual Pedestal Technical Specifications

Page 33

Product Overview 1-17

Specifications

Table 1-6

Pedestal Technical Specifications

Item

Cabinet

Controller

Controller cache

Backup for cache

Mirrored write-back cache

Device channels per controller

Maximum disks per device port

Dual active controllers

Host interface

Drive interface

RAID levels supported

Non-RAID disk support

Sustained I/O rate

RAID 5 sustained transfer rate

Maximum transfer rate

Redundant fans

Redundant power supplies

Global disk spares

EMU

Setup/control lines

Serviceability

RAID manager GUI support

Regulatory approvals

Description

Pedestal with seven (7) disk SBB slots Expansion pedestal with an additional 7 slots

HSZ22

16 MB standard

upgrades to 128 MB for a two controller pair

Standard UPS

Yes

2

14

Yes, order HSZ22-AA and second solutions software kit

UltraSCSI wide differential

UltraSCSI wide single-ended

0, 1, 0+1, 4, 5

Yes (JBOD)

4,400 I/O’s per second per controller pair

28 MB per second per controller pair

40 MB per second per controller pair

Yes

Yes

Yes

Yes, monitors power and temperature

One serial

Hot-swap components

SWCC 2.2 available for all platforms.

UL, CSA, TUV, FCC, CE MARK, C TICK,

BSMI (replaces BCIQ), VCCI

Image 33
Contents Compaq StorageWorks Page Contents RAID Array Controller List of Figures RAID 0 write List of Tables Page About This Guide Maintenance Related Documents Text Conventions Symbols in Text This is a test Rack Stability Compaq Website Product Description Product OverviewRAID Array 3000 pedestal enclosure drives optional RA3000 pedestal subsystem with one controller, 230 Compaq Part NoPedestal Cabinet Pedestal FeaturesPedestal front panel major components Pedestal Components StorageWorks Building Blocks SBBsRAID Array Controller UPS Pedestal Power SuppliesEMU circuit board location Environmental Monitor Unit EMUShows the Pedestal rear panel components UltraSCSI Buses UltraSCSI bus port and default Scsi ID assignmentsUltraSCSI bus configuration switch Connecting the Pedestal to a Host System ItemÂDescription Single Host, Single Adapter CablingDescription Single Host, Dual Adapter/Dual Controller CablingHost System Dual Host, Single Adapter/Single Controller Cabling Pedestal Technical Specifications SpecificationsPhysical Specifications Pedestal Physical and Power SpecificationDimension Power SpecificationsController Overview RAID Array ControllerPage Bridging the gap between the host and the pedestal Controller FeaturesUnits created from storagesets, partitions, and disk drives Specifications Controller SpecificationsController Specifications LED/Reset Switch Interface Controller Reset and LED IndicatorsEnvironmental NameShows the front panel of the controller Flexible RAID Set ConfigurationCustom Components Performance EnhancementsWrite-Back Caching Efficient Write and Read AlgorithmsWrite On Top Write GatheringRAID Levels Supported RAID Levels SupportedPedestal RAID Set Restrictions Max. No. * of DrivesRAID Shows a diagram of a RAID 0 write RAID 0+1 Diagram of a RAID 1 writeRAID 0+1 Example Drives SelectedFunction Diagram of a RAID 4 write Page Diagram of a RAID 5 write Just a Bunch of Drives Jbod Redundant OperationInitialization EnvironmentalMessage Passing FailoverResponse to Various AC Power Conditions Backup Power ManagementCondition ResponseSystem Voltage Voltage MonitoringAcceptable System Voltage Levels Termination VoltageExternal Temperature Temperature MonitoringAcceptable External Temperature Levels Supply VoltageAcceptable Board Temperature Levels Board TemperaturePage Maintenance Pedestal Status and Power LEDs Shows the Pedestal status LEDs SBB Status LEDsActivity LED Fault LED Indication Controller LEDsDisk Drive SBB Status LEDs EMU Error Conditions EMU Error ReportingReplacing Components FRUs Replacing an SBB Removing the Pedestal DoorReplacing an SBB Replacing a power supply Replacing a Power SupplyRemoving the controller from the pedestal Replacing the RAID Array ControllerTools required Replacing the EMU BoardRemove standoffs from UPS and external fault connectors Replacing the UPS Differential/Wide UltraSCSI BusScsi Bus Length and External Cables Reconfiguring the Scsi BusAssigned Slot Device Addresses in the Pedestal Rate Bus LengthMaintenance Shows how to remove the screw and panel Close the side panels and replace the cover screw 11. Remove controller Replacing the Controller Memory Cache Modules12 shows how to release the locking clips 14. Install replacement Simm Expansion Pedestal Option Shows the Expansion Pedestal Expansion Pedestal CabinetExpansion Pedestal Option Expansion Pedestal Components Shows the rear panel power suppliesEMU Reconfiguring Base Pedestal UltraSCSI Bus Remove the side cover from the base pedestal Figure Disconnect Scsi cable Connect Scsi jumper Remove connector knockout plate 10. Connect Scsi cable Set the bus configuration switch to 7 Figures 4-11 13. Reconfigured Scsi bus addresses 14. Connect Scsi cable between pedestals 15. Power cable connections 16. Transfer drives from base to expansion pedestal Second Controller Option Second controller pedestal slot location Second Controller Option KitSaving Existing Configuration Installing the UpgradeUpdating Firmware Updating Firmware Using SwccFirmware update dialog box Updating Firmware Using Serial InterfaceShutting Down the RA3000 Insert Simm into connector Installing Two SIMMs into Second ControllerRemove controller from top slot Replacing Existing ControllerRestoring configuration to new controller Restoring the ConfigurationUpdating Firmware on Second Controller 10. Restored configuration exampleInstalling Original Controller Configuring the RA3000 for the Active Mode Operation Configuring the Dual Controllers Connecting to Your Dual Controller Storage System Verifying the Controller Operating Parameters