Compaq DA-11411 Weights, Input requirements, Output voltage, Specifications, Ambient temperature

Page 22

QuickSpecs

ProLiant BL20p and p-Class system

Technical Specifications

Operating and Performance Specifications for Power Enclosures (North America/Japan)

 

 

Single-Phase Model

Three-Phase Model

Dimensions

Height

5.25 in/13.34 cm

5.25 in/13.34 cm

 

Width

27.15 in/68.96 cm

27.15 in/68.96 cm

 

Depth

17.60 in/44.7 cm

17.60 in/44.7 cm

 

 

 

 

Weights

No hot-plug power supplies

47.5 lb/21.55 kg

47.5 lb/21.55 kg

 

All hot-plug power supplies

99.5 lb/45.13 kg

125.5 lb/56.93 kg

 

 

 

 

Input requirements

Rated input voltage

200 VAC to 240 VAC

200 VAC to 240 VAC line

 

 

 

to line

 

Rated input frequency

50 Hz to 60 Hz

50 Hz to 60 Hz

 

Rated input current per side

24A

24A per phase

 

Rated input power per side

5760 W

9976 W

 

Power cord

1 NEMA L6-30P per side

1 NEMA L15-30 per side

 

 

 

 

Output voltage

Rated output voltage

-48.8 VDC to -54 VDC

-48.8 VDC to -54 VDC

specifications

Rated output current

99A

170A

 

 

Rated output power

4298 W

8310 W

 

Nominal power

4158 W at 208 VAC

7202 W at 208 VAC

 

 

 

 

Ambient temperature

Operating

50° to 95° F/10° to 35° C

50° to 95° F/10° to 35° C

range (See note)

Shipping

-22° to 140°F/-30° to 60°C -22° to 140°F/-30° to 60°C

 

 

 

 

 

Relative humidity,

Operating

20% to 80%

20% to 80%

non-condensing

Non-operating

5% to 95%

5% to 95%

(See note)

 

 

 

 

 

 

 

Wet bulb temperature

Operating

82.4° F/28° C

82.4° F/28° C

 

Non-operating

101.7° F/38.7° C

101.7° F/38.7° C

Note: Operating temperature has an altitude derating of 34° F/1° C per 1,000 ft/304.8 m. No direct sunlight. Upper operating limit is 10,000 ft/3,048 m or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft/ 9,144 m or

30.3KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F/45° C. Altitude maximum for storage is 70 KPa.

DA-11411

World Wide — Version 4 — September 19, 2002

22

Image 22 Contents
QuickSpecs OverviewConfiguration Steps Standard Features Server Blade ProLiant BL p Class RJ 45 patch panel ProLiant BL p Class Interconnect Switch OptionRequired Network Cabling BL p Class Power Distribution Compaq ProLiant BL p Class Power System and RackInformation ProLiant BL p Class Power Power Bus Box Required Power SourceStandard Features ProLiant Essentials Foundation Pack SoftwareIntelligent Manageability OS SupportAvailability Minimum Rack Requirements SecurityRack Airflow Requirements Service and Support Models Options Storage Controllers ProLiant Essentials Value Pack SoftwareCommunications Diagnostic Options BL p-Class Power optionsPower Distribution BL p-Class Server BladeCompaq Rack 10000 Series Compaq Rack 9000 Series OpalRack Options for Compaq Rack 9000 Series Rack Options for Compaq RackSeries Rack Options for Compaq Rack 7000 Series and Telco racksRack Options for Compaq Rack 10000, 9000 and 7000 Series Service and Support OfferingsRack Options for Telco Racks Installation & Start-up Services Memory Memory SlotTechnical Specifications Connector Operating and Performance DimensionsSpecifications for RJ-45 Patch Panel Power requirementsSafety WeightForwarding mode PerformanceAmbient temperature WeightsSpecifications Input requirementsQuickSpecs Max current per power feed Enclosures DimensionsMax total power supported Rated operating voltageOperating and Performance Voltage Specifications for Facility DCMax Rated Power CurrentCompaq Rack Dimensions Total Cabinet Shipping Color QuickSpecs