Christie Digital Systems 38-VIV202-01 user manual Appendix Lamp Replacement, Lamp Replace Counter

Page 39

APPENDIX

LAMP REPLACEMENT

When the life of the Projection Lamp of this projector draws to an end, LAMP REPLACEMENT indicator lights yellow. When a projected image becomes dark or the color of an image becomes unnatural, replacement of Projection Lamp is required.

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

 

 

 

CAUTION

 

 

 

 

For continued safety, replace with a lamp

 

 

 

Do not drop a lamp assembly or touch a glass

 

 

 

 

assembly of same type.

 

 

 

bulb! The glass can shatter and may cause

 

 

 

 

Allow the projector to cool for at least 45

 

 

 

injury.

 

 

 

 

minutes before you open Lamp Cover. The

 

 

 

 

 

 

 

 

 

 

 

 

 

inside of the projector can become very hot.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Follow these steps to replace lamp assembly.

1

Turn off the projector and disconnect the AC plug. Allow the

projector to cool for at least 45 minutes.

2

Remove 2 screws with a screwdriver and open Lamp Cover.

3

Loosen 2 screws with a screwdriver and pull out Lamp Assembly

by grasping Handle.

4

Replace Lamp Assembly with a new one and tighten 2 screws

back. Make sure the Lamp Assembly is set properly. Replace

 

Lamp Cover and tighten 2 screws.

5

Connect the AC Power Cord to the projector and turn it on.

6

Reset Lamp Replace Counter (refer to section “Lamp Replace

Counter” below).

NOTE : Do not reset Lamp Replace Counter when Projection Lamp is not replaced.

 

LAMP COVER

LAMP

HANDLE

ASSEMBLY

 

ORDER REPLACEMENT LAMP

Replacement Lamp can be ordered through your dealer. When ordering Projection Lamp, give the following information to the dealer.

Model No. of your projector : 38-VIV202-01

Replacement Lamp Type No. : 03-000649-01P

(Service Parts No. 610 293 5868)

LAMP REPLACE COUNTER

Be sure to reset Lamp Replace Counter when Lamp Assembly is replaced. When Lamp Replace Counter is reset, LAMP REPLACE Indicator stops lighting.

1

Turn projector on, press MENU button and ON-SCREEN MENU will appear. Press POINT LEFT/RIGHT button(s) to

 

move the red frame pointer to SETTING Menu icon (refer to page 35, 36).

2

Press POINT DOWN button to move the red frame pointer to “Lamp counter reset” and then press SELECT button.

 

The message "Lamp replace counter reset?" is displayed. Move pointer to [Yes] and then press SELECT button.

3

Another confirmation dialog box appears and select [Yes] to reset Lamp Replace Counter.

Do not reset Lamp Replace Counter except after Projection Lamp is replaced.

39

Image 39 Contents
Model To the Owner Voor de klanten in Nederland Safety InstructionsFederal Communication Commission Notice CompliancesTable of Contents Compact Design Digital Zoom for Computer Features and DesignName of Each Part of Projector PreparationSETTING-UP Projector Connecting AC Power CordFor U.S.A. and Canada For Continental Europe Room Light Preparation Positioning ProjectorMoving Projector Preparation Adjustable FeetAudio Input Jacks Connecting ProjectorUSB Connector Series B Terminals of ProjectorTerminals Projector Connecting to ComputerAudio Video Connecting to Video EquipmentOperation of Remote Control Before OperationLaser Pointer Function Focus Button Volume ButtonWired Remote Jack Zoom ButtonReady Indicator TOP Controls and IndicatorsHOW to Operate ON-SCREEN Menu Operating ON-SCREEN MenuFlow of ON-SCREEN Menu Operation Before Operation Menu BAR Guide WindowSound Menu Turning on / OFF Projector Turning on the ProjectorTurning OFF the Projector Keystone Adjustment Adjusting ScreenZoom Adjustment Lens Shift AdjustmentSound Adjustment Input Computer InputSelecting Input Source Selecting Computer SystemAuto PC AdjustmentAuto PC Adjustment Computer Input Automatic MULTI-SCAN SystemComputer Input Manual PC Adjustment Full screen Computer InputDisplay area Display area H1024 x 48.363 60.004 Computer Input Compatible Computer SpecificationsResolution 640 x 31.469 59.940Image 1~4 Picture Image AdjustmentImage Level Select Direct Image Level Select MenuImage Adjust Menu Computer Input Image Level AdjustmentScreen Menu Picture Screen AdjustmentVideo Video InputPAL / Secam / Ntsc / NTSC4.43 / PAL-M / PAL-N Component Video Signal FormatSelecting Video System Video InputCinema Video Input Image Level Adjustment Provides image at a normal video aspect ratio of 4 Setting Setting Menu Setting Menu To change code of Projector To change code of Remote Control UnitOperating Wireless Mouse SETTING/APPENDIXOperating Wireless Mouse InstallationMaintenance AIR Filter Care and CleaningCleaning Projection Lens Lamp Replace Counter Appendix Lamp ReplacementTroubleshooting Service Technical Specifications USB Connector Series B Appendix Configurations of TerminalsPart No -A 610 299 6975 1AA6P1P3325-- MB8K