Draper Video Projector specifications As Soon As Revelation Arrives, Planning, Hanging Unit

Page 1

Installation/Operating Instructions

220 V Revelation Video Projector Mount by Draper

These Installation/Operating Instructions are available in the official language of the country where you purchase the product. Please contact your distributor to request a copy.

Vous pourriez demander les instructions d’installation et d’opération traduises dans la langue officielle du pays ou vous achetez le produit. Veuillez demander à votre distributeur.

Die Gebrauchsanweisung für Installation und Konstruktion sind in der offiziellen Sprache des Landes, indem Sie das Produkt gekauft haben, vorhanden. Fragen Sie die jeweilige Verkaufs-Abteilung.

Caution

Read instructions completely before proceeding.

Follow instructions carefully. Installation contrary to instructions invalidates warranty.

Take great care when handling both first surface mirrors. They will usually come covered with a protective film. Remove this fi lm after installation and prior to projecting images. If cleaning is necessary, do

so very lightly with glass cleaner and a soft, lint free cloth.

Do not obstruct operation of door with fingers or any object. Serious injury or damage could result.

The Revelation is not designed to act as a structural support of ceiling

framing. However, the trim frame is designed to support ceiling T-grid, tiles and drywall. Equipment should not be allowed to rest on door at any time.

Entire bottom of unit must be unobstructed to permit proper operation. Suffi cient clearance (432mm minimum) must be allowed below door.

A minimum clearance of 458mm is required above ceiling level for model B or 347mm for Model A, if plenum housing is used. If no plenum, the minimum clearance is 331mm for both models.

Unit must be installed level (use a carpenter’s level).

Unit operates on 220 V a.c. 60 hz. current.

Note: Unit has been thoroughly inspected and tested at factory and found to be operating properly prior to shipment.

As Soon As Revelation Arrives

Open carton and inspect for damage.

Locate the following parts:

A.The unit itself

B.Controls

Planning

Based on screen location and projector specifi cations, determine proper position for projector installation. (First see "Choose a projector based on its light path" on page 3. Then read "Where to install the

Revelation" below.)

Confi rm that there is at least 458mm available above the ceiling for Model B or 347mm for Model A, if plenum housing is used. If no plenum, the minimum clearance is 331mm for both models.

Arrange to provide service access to electrical control box and plenum housing.

If connecting duct work to the plenum housing, plan for position and length of duct work. (See guidelines under "Installing the Plenum Kit" on page 6.)

Metric Conversion 1 inch = 25.4 mm 1 inch = 2.54 cm

Where to install the Revelation

To determine where to mount the Revelation, you need to know the following:

The projector manufacturer’s recommended throw distance (TD). Typically, a minimum and maximum range is provided per screen size. Select a throw distance that is 6" greater than the minimum and 6" less than the maximum stated. We recommend the average of the two numbers. For example, if the range given is 228" max. and 142½" min., then use a number between 222" and 148½". We recommend using the average of

185¼" as the TD.

The distance from the center line of the lens to the bottom of the projector’s feet (CL). To find the mounting point (m = back edge of the rough cut) use the following formula:

y = 15" + CLz = TD – y m = z + 8"

Remember:

CL = Distance from center line of lens to bottom of projectors feet.

TD = Manufacturer’s horizontal throw distance for the selected screen size. m = Calculated mounting point (mounting point is back edge of rough cut as measured from screen surface.)

As an example, if you are using a projector with recommended throw distance (TD) of 185¼" for a 100" diagonal image, and its CL dimension is 4", calculate

the mounting point as follows:

 

 

y = 15" + CL

z = TD – y

m = z + 8"

y = 15" + 4"

z = 185¼" – 19"

m = 166¼" + 8"

y = 19"

z = 166¼"

m = 174¼"

 

In the example above, the distance from the screen to the back edge of the rough cut would be 174¼". (Formula has a ± 6" accuracy).

 

y

 

m

= C

z

L

Formula to find m

(mounting point is back edge of rough cut farthest away from projection screen).

y = 15" + CL

z = TD – y

m = z + 8"

where:

CL = centerline of lens to bottom feet

 

TD = throw distance

 

 

Accuracy: ± 6"

 

Hanging Unit

The Revelation may be installed in a variety of ways. Typically, it is recessed above the ceiling and supported by six (6) 3/8" threaded mounting rods. The bottom of the main pan should be recessed approximately 76mm above the fi nished ceiling. The threaded rods should pass through mounting holes supplied in each corner and secured by nuts above and below. The unit should then be guy wired or blocked to prevent swinging.

All installations should observe the following guidelines:

Installer must ensure that all fasteners and supports are of adequate strength to securely support Revelation and projector.

Fastening methods must be suitable for mounting surface, and securely anchored so that vibration or abusive pulling on unit will not weaken

installation.

Unit should be level, with weight shared more or less equally by all six threaded mounting rods.

Copyright © 2007 Draper Inc. Form Revelation220V_Inst07

Printed in U.S.A.

Continued on page 2

Image 1
Contents As Soon As Revelation Arrives Where to install the RevelationPlanning Hanging UnitRevelation by Draper Choose a projector* based on its light path Revelationby DraperRevelation Dimensions T1 Wiring Low Voltage Multiple Station and Remote ControlPrimary Side Secondary Side Revelation by DRAPERPage 6 Field Installation of Plenum KitNum Excessive heat buildup inside the unitPlenum Operating Instructions VIC 12 or VIC 12 Modified Installation Part List VIC12 Kit Installation Instructions➀ Close the door to the Revelation ➂ Remove the covers from the electrical enclosure