Draper Video Projector VIC12 Kit Installation Instructions, ➀ Close the door to the Revelation

Page 8

220 V Revelation by DRAPER

VIC12 Kit Installation Instructions

Page 8 of 8

The VIC 12 KIT includes all the components necessary for the VIC 12 to work with the Revelation. Follow these steps to install the components in this KIT.

Close the door to the Revelation.

DISCONNECT POWER TO THE REVELATION.

Remove the covers from the electrical enclosure.

Attach the pre-wired limit switch [1] to the shaft mounting bracket which is closest to the motor as shown in FIGURE #1. Using the

#6–32 x 1" [2] long screws and #6 lock washers [2] provided.

Run the wires through the open grommet in the end of the electrical enclosure that is toward the motor as shown in FIGURE #1 and connect them as follows:

Connect the black wire to screw #1 of TB2

Connect the blue wire to screw #2 of TB2. (Be sure that wires do not interfere with moving linkage or the sliding inner pan)

Put the 12V ACTIVATOR LEVER [3] onto the shaft as shown in Figure #2. The 12V ACTUATOR LEVER will need to be spread out before it will fi t onto the shaft. The door to the Revelation must be closed before going on to step #7

Position the 12V ACTUATOR LEVER by rotating it into the limit switch until the limit switch clicks and secure the lever onto the shaft using the #10-32 screw [4] and lock washer [5] supplied with the lever. (Be sure that the screw on the lever is tightened so that the lever does not twist on the shaft.)

FIGURE #1

CR 1

TB 2

 

CR 2

9 10

Motor

 

C 1

5 6 7 8

Blue

3 4

 

 

1 2

 

Black

Pre-wired limit switch

FIGURE #2

12V actuator lever

12V Actuator lever

After the VIC 12 [7] is installed with the screen, run the wiring to the Revelation using the cord strain relief [6] and connect to TB1 as shown in the Revelation wiring diagram.

Put the covers back on to the electrical enclosure.

Reconnect power to the revelation.

Rotate lever until the limit switch clicks. Tighten lever

onto shaft.

Pre-wired limit switch

VIC 12 OR VIC 12 MODIFIED INSTALLATION PART LIST

ITEM #

DESCRIPTION

QTY

1

PRE-WIRED LIMIT SWITCH

1

2

SCREW #6–32 X 1"(25.4mm) LONG

2

 

PHIL PAN HD W/ EXT LOCK WASHER

 

3

12v ACTUATOR LEVER

1

4

SCREW #10–32 X 3/8" (9.525mm) LONG SHCS

1

5

WASHER #10–.190" I.D. X .375" (9.525mm) O.D.

1

 

ZINC INTERNAL TOOTH

 

6

FITTING CORD CRIMP STRAIN RELIEF

1

7

VIC 12 OR VIC 12 MODIFIED

1

TOOLS NEEDED

MED POINT PHILLIP SCREW DRIVER I/8" FLAT BLADE SCREW DRIVER 3/16" ALLEN WRENCH

www.draperinc.com (765) 987-7999

Image 8
Contents Where to install the Revelation As Soon As Revelation ArrivesPlanning Hanging UnitRevelation by Draper Revelationby Draper Choose a projector* based on its light pathRevelation Dimensions Primary Side Secondary Side Low Voltage Multiple Station and Remote ControlT1 Wiring Field Installation of Plenum Kit Revelation by DRAPERPage 6Num Excessive heat buildup inside the unitPlenum Operating Instructions VIC12 Kit Installation Instructions VIC 12 or VIC 12 Modified Installation Part List➀ Close the door to the Revelation ➂ Remove the covers from the electrical enclosure