BOXLIGHT CP322ia user manual Option Menu

Page 36

MULTIFUNCTIONAL SETTINGS (continued)

OPTION Menu

With the OPTION menu, the five items shown in the Table below can be performed.

Please perform each operation in accordance with the instructions in the Table.

MENU

MAIN

VOLUME

PICTURE-1

AUTO OFF

PICTURE-2

WHISPER

INPUT

LAMP TIME

SCREEN

FILTER TIME

OPTION

 

12

: SELECT

Example : OPTION Menu

(VOLUME)

OPTION Menu

Item

 

 

Description

VOLUME

Adjust Volume: High

Low

AUTO OFF

Adjust AUTO OFF Time:

Long (MAX. 99 min.) Short (Min. 1 min.) (DISABLE: 0 min.) The system automatically enters the standby mode if no signal is received within the set time. This function is inactive when DISABLE (0 min.) is selected.

WHISPER

Select WHISPER Mode:

NORMAL WHISPER

When WHISPER is selected the WHISPER mode is activated. In the WHISPER mode, acoustic noise and screen brightness are reduced.

Refer to LAMP TIME: When set, this function displays the total time the projector lamp has been used since new.

Reset LAMP TIME [Use this function only when the lamp has been replaced!]:

Depress the RESET button for at least 3 seconds while lamp time is being displayed. The reset menu will then appear. After you replace the lamp with a

LAMP TIME new lamp, select RESET on the menu with the button.

Do not reset the lamp time unless you have replaced the lamp. And, always reset the lamp time when replacing the lamp. The message functions will not operate properly if the lamp time is not reset correctly.

Before replacing the lamp, carefully read the descriptions headed "THE LAMP".

Refer to FILTER TIME: This function displays the total time the air-filter has been used since new.

Reset FILTER TIME [Use this function only when the filter is cleaned or replaced!]:

Depress the RESET button for at least 3 seconds while filter time is being

displayed. The reset menu will then appear. After you replace the filter, select

FILTER TIME

button.

RESET on the menu with the

Do not reset the filter time unless you have cleaned or replaced the filter. And, always reset the filter time when cleaning or replacing the filter. The message functions will not operate properly if the filter time is not reset correctly.

Before cleaning or replacing the filter, carefully read the descriptions headed "THE AIR FILTER".

6

Image 36
Contents CP322ia Contents Projector Features For the remote ControlPower cord CableOnly use the power cord that came with the projector Devices you will be using to the projectorPower cord Connect your devices to the projectorPart Names ReferenceAuto button Blank button Volume button Mute button RGB button Search button STANDBY/ON buttonVideo button 15 Aspect button Magnify buttons Freeze button Keyboard buttonsSetting UP the Projector Adjusting the Projectors Elevator FeetAdjusting the Screen Size and Projection Distance ScreenConnecting Your Devices Ports and Cables Function Projector Port Connection CablesConnecting Your Devices Connecting to a ComputerConnecting to a DVD Player Connecting to a VCRConnecting to a Display Monitor Using the Remote Control Putting batteries into the remote control unitOperating the remote control Turning on the Power PrecautionsPress the STANDBY/ON button control panel or remote control Remove the lens capSelecting an Input Signal If selecting video input Press the Video buttonPress the Input button Turning OFF the Power Adjusting the Volume Press the Volume buttonPress the , buttons to adjust the volume Temporarily Muting the SoundAdjusting the Position Use the , , , buttons to adjust the positionPress the Position button Using the Automatic Adjustment Feature Automatic Adjustment for RGB InputAutomatic Adjustment for Video Input Press the Auto buttonCorrecting Keystone Distortions Press the Keystone buttonAs illustrated on the right, a dialog will appear On the screen to aid you in correcting the distortionUsing the Magnify Feature Freezing the ScreenPress the Magnify on button Press the , buttons to zoom in and out of the selected areaSignal Searching Selecting the Aspect RatioTemporarily Blanking the Screen Using the Menu Functions Press the / buttons to adjust the levelPress the Menu button Available Functions Remote Control Operation Operating the PC ScreenHigh Voltage High Temperature High Pressure LampDo not use the projector with the lamp cover removed Lamp Replacing the lampAIR Filter Caring for the air filterAIR Filter Replacing the air filterCaring for the cabinet and remote control transmitter Other CareCaring for the inside of the projector Caring for the lensFor Technical see the end of this manual Multifunctional Settings Main MenuMain Menu Picture 1 Menu Picture 2 Menu PICTURE1 Menu PICTURE2 MenuInput Menu Input MenuAuto VideoScreen Menu Screen MenuBlank Start UPOption Menu Option MenuRelated Messages Regarding the Indicator Lamps Power Lamp TempPhenomena That May Easily Be Mistaken for Machine Defects Vol.2-2Vol.2-3 Vol.2-6Specifications Dimension DiagramSpecification Unit mmWarranty and AFTER-SERVICE Page Signal Connector PIN Assignment RGB in 1/2Sub 15-pin Shrink Example of Computer Signal Resolution FH kHz FV Hz Rating Signal mode Display modeInitial SET Signals Connection to the Mouse Control ADB MouseSerial Mouse USB MouseCommand data Consist of header 7 bytes + command data 6 bytesRS-232C Communication ProtocolRequesting projector status Get command Changing the projector settings Set commandUsing the projector default settings Reset Command Increasing the projector setting value Increment commandCommand data chart 日本語Be EF BA D2 Be EF FD D3 Be EF Ntsc PAL Regulatory Notices Limited Warranty Disclaimer of Unstated Warranties