Acer P1200, P1303W, P1203, P1100 Troubleshooting, Image Problems and Solutions, Problem Solution

Page 42

English

32

Appendices

Troubleshooting

If you experience a problem with your Acer projector, refer to the following troubleshooting guide. If the problem persists, please contact your local reseller or service center.

Image Problems and Solutions

#

Problem

 

 

Solution

 

 

 

 

1

No image appears

Connected as described in the "Getting Started"

 

onscreen

 

section.

 

 

Ensure none of the connector pins are bent or

 

 

 

broken.

 

 

Check if the projector lamp has been securely

 

 

 

installed. Please refer to the "Replacing the Lamp"

 

 

 

section.

 

 

Make sure you have removed the lens cap and the

 

 

 

projector is switched on.

 

 

 

 

2

Partial, scrolling

Press "RESYNC" on the remote control or control panel.

 

or incorrectly

For an incorrectly displayed image:

 

displayed

 

image(For PC

 

Open "My Computer," open the "Control

 

(Windows 95/98/

 

 

Panel," and then double-click the "Display"

 

2000/XP))

 

icon.

 

 

 

Select the "Settings" tab.

 

 

 

Verify that your display resolution setting is

 

 

 

lower than or equal to UXGA (1600 x 1200).

 

 

 

Click the "Advanced Properties" button.

 

 

If the problem still appears, change the monitor display

 

 

you are using and follow the steps below:

 

 

 

Verify that the resolution setting is lower than

 

 

 

or equal to UXGA (1600 x 1200).

 

 

 

Click the "Change" button under the

 

 

 

"Monitor" tab.

 

 

 

Click "Show all devices". Next, select "Standard

 

 

 

 

monitor types" under the SP box, and choose

 

 

 

 

the resolution mode you need under the

 

 

 

"Models" box.

 

 

 

Verify that the resolution setting of the

 

 

 

 

monitor display is lower than or equal to UXGA

 

 

 

 

(1600 x 1200).

 

 

 

 

 

Image 42
Contents Page Page Information for your safety and comfort Turning the product off before cleaningUsing electrical power Additional safety information Product servicingPage Lamps contain Mercury, Dispose Properly Disposal instructionsMercury advisory To protect your hearing, follow these instructionsPrecautions Usage notesContents Regulations and safety notices Product Features IntroductionPackage Overview Front / upper side Projector OverviewProjector Outlook Rear sideSee the contents in Turning the Projector On/Off section Temp Indicator LEDControl Panel # Icon Function Description Changes the active sourceRemote Control Layout HideRGB Connecting the Projector Getting StartedTurning the Projector On/Off Turning on the ProjectorLens cap Turning the projector off Elevator foot release button Tilt adjusting wheel Adjusting the Projected ImageAdjusting the Height of Projected Image To raise the imageHow to optimize image size and distance P1100/P1200/P1203/P1206 seriesTop Maxscreensize P1303W series88 x 97 x Height Image P1303W series English Installation menu User ControlsAcer Empowering Technology Using the OSD menus Onscreen Display OSD MenusColor Image TintTo move the image left Correct 3D display DDD TriDef Media Player Trial Setting ManagementSecurity Lock User Startup Screen Timer AudioLanguage Troubleshooting Image Problems and SolutionsProblem Solution English English OSD Messages Condition Message ReminderProblems with the Projector Condition SolutionLED & Alarm Definition Listing LED MessagesReplacing the Lamp Ceiling Mount Installation Attach the ceiling bracket to the ceiling rod 60.0 mm Specifications DLPBelow items are for P1203/P1206/P1303W series only Compatibility modes VGA AnalogHdmi Digital PowerBook G4 119.85 77.2064.00 59.94 31.47 576i 120Hz for 3D mode only27.00 31.25FCC notice Operation conditionsRemarque à lintention des utilisateurs canadiens Declaration of Conformity for EU countriesRadio device regulatory notice General List of applicable countries Declaration of Conformity Oct Federal Communications Commission Declaration of Conformity