No | Symptom | Procedure | |
|
| - Ensure the Signal Cable and Source work | |
|
| (If you connect multiple sources at the same time, use the | |
|
| "Source" button switch) | |
|
| - Ensure all connectors are securely connected and aren’t | |
|
| broken | |
4 | No Image | - Check Main Board | |
|
| - Check DMD Board | |
|
| - Check DMD Chip | |
|
| - Check Color Wheel | |
|
| - Check Engine Module | |
|
|
| |
5 | Mechanical Noise | - Check Color Wheel | |
- Check Fan Module | |||
|
| ||
|
|
| |
|
| - Check if the Main Board and the DMD Board are | |
|
| assembled properly | |
6 | Line Bar/Line Defect | - Check Main Board | |
|
| - Check DMD Board | |
|
| - Check DMD Chip | |
|
|
| |
|
| - Do "Reset (All data)" of the OSD Menu | |
|
| - Ensure that the signal cables and source are work as well | |
|
| - Check Lamp Driver and waveform | |
7 | Image Flicker | - Check Lamp Module | |
- Check Color Wheel | |||
|
| ||
|
| - Check Photo Sensor and clean Photo Sensor | |
|
| - Check DMD Board | |
|
| - Check Main Board | |
|
| - Do "Reset (All data)" of the OSD Menu | |
|
| - Adjust Color Wheel Index | |
8 | Color Abnormal | - Check Main Board | |
|
| - Check DMD Board | |
|
| - Check Color Wheel |
X1161/X1261/X1161A/X1161N/X110/H5360 Confidential
3-