Bosch Appliances DVA-08K manual Subsystem Components, 2.3.1, LCD Panel

Page 12
Subsystem Components

12 en IntroductionRAID Subsystem DVA-08K Installation Manual

2.3

Subsystem Components

 

All the active components on the subsystem can be accessed through either the front or rear

 

panel. The modular design of the active components facilitates their easy installation and

 

removal. Hot-swap mechanisms are incorporated to eliminate power surges and signal

 

glitches that might occur while removing or installing these modules.

2.3.1

LCD Panel

Fig. 2.6 Opening the Front Handle

The LCD panel shown in Figure 2.6 consists of a 16 characters x 2 rows LCD screen with push buttons, a mute button, and LED status indicators. The LCD front panel provides full access to all array configurations and monitoring. After powering up the subsystem, the initial screen will show the subsystem model name. A different name can be manually assigned to the sub- system or different drive arrays. This will enable easier identification in a topology consisting of numerous arrays.

Fig. 2.7 Front Panel Retention Latch

To access drive bays in the left- or right-hand side column, first flip the retention latches (see Figure 2.7) on the enclosure front handles, and then swing the handles to the left- and right- hand sides. To close the handles (see Figure 2.8), swing the handles toward the system; gen- tly press the handles until a click is heard. The latches will keep the handles in place.

Fig. 2.8 Closing the Front Handles

F.01U.027.797 V2 2008.08

Bosch Security Systems

Image 12
Contents RAID Subsystem DVA-08K DVA-08K SCSI Premium SeriesPage Table of Contents RAID Subsystem DVA-08K Installation ManualTable of Contents en Bosch Security SystemsSubsystem Connection and Operation Safety Precautions Precautions and InstructionsESD Precautions Warnings and CertificationsReorient or relocate the receiving antenna Introduction Product OverviewSCSI Host Ports Active Components Physical Dimensions Enclosure Chassis2.2.1 Chassis Overview2.2.4Hard Drive Numbering 2.2.5Rear Panel Overview2.2.6Backplane Board Subsystem Components 2.3.1LCD Panel 2.3.2Drive Trays 2.3.3The RAID Controller Module Controller Module Interfaces2.3.4Battery Backup Unit DIMM ModulePower Supply Units 2.3.52.3.6 Cooling Fan ModulesAdvanced Fault-Preventative Operation Intelligent Dual Speed OperationLED Indicators Audible AlarmsSubsystem Monitoring 2.4.1Hot-Swappable Components 2.5.1Hot-Swap Capabilities 2.5.2Hardware Installation Installation PrerequisitesPrecautions and Instructions Static-Free InstallationBBU Warnings and Precautions 3.2.1Install or replace the BBU module only with a BBU module supplied by your subsystem vendor. Use of battery cells provided by another source will void our warranty General Installation Procedure Installation Procedure FlowchartSection 5.4 Power On Installation ProcedureConsiderations for Installation Site and Chassis 3.5Rackmounting3.5.1 3.5.23.6Drive Tray Installation 6. Once all drive trays are installed, the RAID subsystem will poll the drive channels and rec- ognize the drives and scan them in automatically Subsystem Monitoring Subsystem Monitoring OverviewStatus-indicating LEDs 4.2.1Brief Overview of the LEDs ComponentPower Status 4.2.2Drive Tray LEDs4.2.3 Controller Module LEDs4.2.4 Ethernet Port LEDsName Link Status4.2.5BBU Module LED 4.2.6PSU LED 4.2.7LCD Keypad PanelPOWER 4.2.8Cooling Fan Module LEDBUSY Audible Alarm Default Threshold Values4.3.1 Upper Threshold4.4I2C Monitoring 4.3.2Failed Devices Basic Configuration Rules Subsystem Connection and OperationSCSI Connection Overview 5.2.1SCSI Cables 5.2.25.2.3 SCSI TerminationDefault Channel Settings Host Connection TopologyModel Host ChannelsPower On Power On ChecklistPower On Sequence Power On ProcedurePower On Status Check 5.4.45.4.5LCD Screen 40 en Subsystem Connection and Operation Power Off Procedure Subsystem Maintenance General Notes on Component Replacement3. BBU module - Section 6.4 Replacing a Faulty BBU OverviewNotes on Controller Module Maintenance Replacing Controller Module Components6.2.1Overview 6.2.26.2.4 Replacing the Controller ModuleMemory Module Installation Overview DIMM Module InstallationReplacing or Upgrading Memory Modules 6.3.13. Gently retrieve the DIMM module out of the DIMM socket. See Figure Replacing a Faulty BBU Notes on PSU Module MaintenanceReplacing a Failed PSU Module 6.5.1The screw is located below the extraction lever, beside the LED indicator, and can be hid- den from sight 7. Insert the new PSU module into the subsystem Once the previously removed cooling module has been installed, insert the new PSU module into the subsystem. Make sure the extraction lever is in its downright position so that the saddle notches on the lower edges of the handle can lock on to the edge metal brackets along the chassis inner walls. Push the PSU into the slot and pull the handle upwards to secure the module Notes on Cooling Fan Module Maintenance Replacing a Failed Cooling Fan Module6.6.1 6.6.2Replacing a Cooling Fan ModuleDrive Tray Maintenance Notes on Hard Drive Maintenance6.7.1 6.7.2Replacing a Failed Hard DriveDrive type The subsystem can use either SATA-II or SATA-I hard drives Fig. 6.10 Installing a SATA Hard Drive Appendix Technical Specifications Environmental SpecificationsPower Requirements DimensionsSafety Requirements Warning AlarmsShock VibrationController Specifications ConfigurationSpecifications 7.1.1Drive Tray Specifications Power Supply SpecificationsCooling Module Specifications RAID ManagementFault Tolerance Management Appendix Spare Parts and Accessories Spare Parts ListSpare Parts 8.1.1Accessories and Optional Items SCSI Port VHDCI Connector Pinouts Appendix PinoutsCOM1 Cable DB9 and Audio Jack Pinouts CN1 Pin NumberPin Name CN2 Pin NumberMain Power Null ModemEthernet Port Pinouts 10 Index warning alarms terminal emulation program 17 terminal management 14 threshold valuesunder charge ventilation clearancePage Bosch Security Systems Robert-Koch-Straße D-85521 OttobrunnGermany Telefon