Bosch Appliances DVA-08K manual en Subsystem Connection and Operation, F.01U.027.797 V2

Page 40
40 en  Subsystem Connection and Operation

40 en Subsystem Connection and Operation

RAID Subsystem DVA-08K Installation Manual

 

 

This screen appears when the PSUs are turned on.

Proceeding with controller self-test.

Self-test completed.

DVA-08K

Verifying installed cache memory.

DVA-08K

System is ready. You can now start to config- ure the subsystem.

F.01U.027.797 V2 2008.08

Bosch Security Systems

Image 40
Contents RAID Subsystem DVA-08K DVA-08K SCSI Premium SeriesPage Table of Contents RAID Subsystem DVA-08K Installation ManualTable of Contents en Bosch Security SystemsSubsystem Connection and Operation Safety Precautions Precautions and InstructionsESD Precautions Warnings and CertificationsReorient or relocate the receiving antenna Product Overview IntroductionSCSI Host Ports Active Components Physical Dimensions Enclosure Chassis2.2.1 Chassis Overview2.2.4Hard Drive Numbering 2.2.5Rear Panel Overview2.2.6Backplane Board 2.3.1 Subsystem ComponentsLCD Panel 2.3.2Drive Trays 2.3.3The RAID Controller Module Controller Module Interfaces2.3.4Battery Backup Unit DIMM ModulePower Supply Units 2.3.52.3.6 Cooling Fan ModulesAdvanced Fault-Preventative Operation Intelligent Dual Speed OperationLED Indicators Audible AlarmsSubsystem Monitoring 2.4.1Hot-Swappable Components 2.5.1Hot-Swap Capabilities 2.5.2Hardware Installation Installation PrerequisitesPrecautions and Instructions Static-Free InstallationBBU Warnings and Precautions 3.2.1Install or replace the BBU module only with a BBU module supplied by your subsystem vendor. Use of battery cells provided by another source will void our warranty General Installation Procedure Installation Procedure FlowchartSection 5.4 Power On Installation ProcedureConsiderations for Installation Site and Chassis 3.5Rackmounting3.5.1 3.5.23.6Drive Tray Installation 6. Once all drive trays are installed, the RAID subsystem will poll the drive channels and rec- ognize the drives and scan them in automatically Subsystem Monitoring Subsystem Monitoring OverviewStatus-indicating LEDs 4.2.1Brief Overview of the LEDs ComponentPower Status 4.2.2Drive Tray LEDs4.2.3 Controller Module LEDs4.2.4 Ethernet Port LEDsName Link Status4.2.5BBU Module LED 4.2.6PSU LED 4.2.7LCD Keypad Panel4.2.8Cooling Fan Module LED POWERBUSY Audible Alarm Default Threshold Values4.3.1 Upper Threshold4.3.2 4.4I2C MonitoringFailed Devices Basic Configuration Rules Subsystem Connection and OperationSCSI Connection Overview 5.2.1SCSI Cables 5.2.25.2.3 SCSI TerminationDefault Channel Settings Host Connection TopologyModel Host ChannelsPower On Power On ChecklistPower On Sequence Power On Procedure5.4.4 Power On Status Check5.4.5LCD Screen 40 en Subsystem Connection and Operation Power Off Procedure Subsystem Maintenance General Notes on Component Replacement3. BBU module - Section 6.4 Replacing a Faulty BBU OverviewNotes on Controller Module Maintenance Replacing Controller Module Components6.2.1Overview 6.2.26.2.4 Replacing the Controller ModuleMemory Module Installation Overview DIMM Module InstallationReplacing or Upgrading Memory Modules 6.3.13. Gently retrieve the DIMM module out of the DIMM socket. See Figure Replacing a Faulty BBU Notes on PSU Module MaintenanceReplacing a Failed PSU Module 6.5.1The screw is located below the extraction lever, beside the LED indicator, and can be hid- den from sight 7. Insert the new PSU module into the subsystem Once the previously removed cooling module has been installed, insert the new PSU module into the subsystem. Make sure the extraction lever is in its downright position so that the saddle notches on the lower edges of the handle can lock on to the edge metal brackets along the chassis inner walls. Push the PSU into the slot and pull the handle upwards to secure the module Notes on Cooling Fan Module Maintenance Replacing a Failed Cooling Fan Module6.6.1 6.6.2Replacing a Cooling Fan ModuleDrive Tray Maintenance Notes on Hard Drive Maintenance6.7.1 6.7.2Replacing a Failed Hard DriveDrive type The subsystem can use either SATA-II or SATA-I hard drives Fig. 6.10 Installing a SATA Hard Drive Appendix Technical Specifications Environmental SpecificationsPower Requirements DimensionsSafety Requirements Warning AlarmsShock VibrationController Specifications ConfigurationSpecifications 7.1.1Drive Tray Specifications Power Supply SpecificationsCooling Module Specifications RAID ManagementFault Tolerance Management Appendix Spare Parts and Accessories Spare Parts ListSpare Parts 8.1.1Accessories and Optional Items SCSI Port VHDCI Connector Pinouts Appendix PinoutsCOM1 Cable DB9 and Audio Jack Pinouts CN1 Pin NumberPin Name CN2 Pin NumberNull Modem Main PowerEthernet Port Pinouts 10 Index warning alarms terminal emulation program 17 terminal management 14 threshold valuesunder charge ventilation clearancePage Bosch Security Systems Robert-Koch-Straße D-85521 OttobrunnGermany Telefon