3M X70, X80 manual Option Menu, Speaker, IR Remote ID, Filter Time

Page 33

Multifunctional Settings (continued)

OPTION Menu

With the OPTION menu, the items shown in the table below can be performed. Perform each operation in accordance with the instructions in the table below.

MENU

MAIN

VOLUME

16

PICTURE-1

SPEAKER

TURN ON

PICTURE-2

IR REMOTE

 

INPUT

IR REMOTE ID

ALL

AUTO

LAMP TIME

1234 h

SCREEN

FILTER TIME

4321 h

OPTION

SERVICE

 

NETWORK

PIN LOCK

TURN ON

: SELECT

 

 

Item

 

 

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

VOLUME

Adjust the volume using the /

buttons. :

 

 

 

 

High

Low

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Select the TURN ON or the TURN OFF using the /

buttons. :

 

 

SPEAKER

TURN ON

TURN OFF

 

 

 

 

 

 

 

When the TURN ON is selected, the built-in speaker works.

 

 

 

 

 

 

 

 

 

Select a remote sensor using the

/ button (1), then switch it

 

 

 

 

OPTION

 

 

using the ENTER button (2). :

 

 

 

IR REMOTE

 

 

 

 

 

1:FRONT

 

IR REMOTE

(1) 1:FRONT

2:TOP

3:REAR (2) (Off)

(On)

 

 

 

2:TOP

 

 

memo A sensor cannot be turned off when the other two are off.

 

3:REAR

 

 

 

ENT

 

 

Always at least one sensor is on.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Select a number as an ID number for remote control using the /

buttons. :

 

ALL

1

2

3

 

 

 

 

 

 

 

The projector is controlled by the remote control whose ID CHANGE switch is

IR REMOTE ID

set into the position of the same number as this number. When the ALL is

 

selected, the projector is controlled by a remote control irrespective of the

 

position of the ID CHANGE switch.

 

 

 

 

 

memo Please refer to the section “Using The Remote ID Feature”.

 

 

 

 

 

 

 

Pressing the RESET button for about 3 seconds displays the LAMP TIME menu.

 

Select the RESET using

button to reset the timer. :

 

 

 

 

 

RESET

 

CANCEL

 

 

 

 

 

 

LAMP TIME

Selecting the RESET resets the count of the lamp timer to 0.

 

 

memo Perform this function only when you have replaced the lamp. The lamp

 

 

timer counts the used time of the current lamp, to display the messages about

 

the lamp. Incorrect performing causes incorrect operation of the messages.

 

memo About replacing the lamp, please refer to the section” Lamp”.

 

 

 

 

 

 

 

Pressing the RESET button for about 3 seconds displays the FILTER TIME

 

menu.

 

 

 

 

 

 

 

 

 

 

Select the RESET using

button to reset the timer. :

 

 

 

 

 

RESET

 

CANCEL

 

 

 

 

 

 

FILTER TIME

Selecting the RESET resets the count of the lamp timer to 0.

 

 

memo Perform this function only when you have cleaned or replaced the air

 

 

filter. The filter timer counts the used time of the air filter after cleaning or

 

replacement, to display the messages about the air filter. Incorrect performing

 

causes incorrect operation of the messages.

 

 

 

 

 

memo About caring for the air filter, please refer to the section “Air Filter”.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(This table is continued to the following page.)

33

Image 33
Contents Thank you for purchasing this projector X70/X80Preparation Projector FeaturesContents Projector Part NamesProjector Front/Right Projector Rear/LeftRemote Control Remote ControlControl Buttons ESCArrangement Setting UpScreen Lens center ScreenUsing The Lens Shift Buttons X80 only Adjusting The Projectors ElevatorConnecting Your Devices If using a BNC input If using a M1-D input to mouse controlComputerProjector CR/PR CB/PBIf using a component signal If using a s-video signalIf using a Scart RGB input VCR/DVD Player ProjectorMonitorProjector Connecting The Power SupplySpeakerProjector Guide and the followingPeople. The laser beam can cause vision problems Remote ControlAbout The Laser Pointer Putting BatteriesUsing The Remote ID Feature Operating The Remote ControlUsing The Mouse/Keyboard Control Function Power ON/OFF Turning On The PowerTurning Off The Power Operating Selecting An Input SignalAt a M1-D signal Using The Automatic Adjustment FeatureAt a RGB signal not M1-D At a video signal At a RGB signalCorrecting The Keystone Distortion Adjusting The Picture PositionDialog and complete this operation Will appear on the screen to aid youAdjusting The Volume Muting The SoundTemporarily Blanking The Screen Freezing The Screen Using The Magnify FeaturePress the Magnify on Button Will appear on the screen to aidSelecting An Audio Input Displaying The Child WindowMultifunctional Settings Using The Menu FunctionsEx. Turning off the built-in speaker Main Menu PICTURE-1 Menu PICTURE-1 Menu LOAD1 LOAD2 LOAD3 LOAD4SAVE1 SAVE2 SAVE3 SAVE4 PICTURE-2 Menu PhasePosition SizeComponent Input MenuVideo 3D-YCSInput Menu Power OFF AdjustPower on Auto MenuAuto Menu Displays the picture of retrieved signalM1-D Rgb SearchBlank Screen MenuStart UP Menu PositionHow to register your picture as the MyScreen Screen MenuMessage Speaker Option MenuIR Remote IR Remote IDOption Menu Setup Network MenuDhcp Network Setting Up Click Return to top Click Reboot to complete this operationEx. Case of IP Address = Lamp Replacing The Lamp KnobLamp door Caring For The Air Filter Air FilterOther Care Caring For The Cabinet And Remote ControlCaring For The Inside Of The Projector Caring For The LensRelated Messages TroubleshootingRelated Messages Regarding The Indicator Lamps Regarding The Indicator Lamps Phenomena That May Easily Be Mistaken For Machine Defects Phenomena That May Easily Be Mistaken For Machine Defects CR/PR, CB/PB, Y SpecificationsAccessories Part Number AccessoriesHow to Order Not Included with Basic Packet Part NumberDN00591 X70/X80OGENG

X70, X80 specifications

3M, a global leader in innovation and technology, has made significant contributions to various industries with its advanced products. Among its noteworthy offerings are the 3M X80 and X70 tapes, which have garnered attention for their unique properties and applications. These tapes are designed to meet the diverse needs of professionals across different sectors, including automotive, industrial, and construction.

Starting with the 3M X80 tape, this product is engineered for demanding applications that require high tensile strength and durability. One of its main features is its robust adhesive, which provides strong bonding capabilities on various surfaces. The X80 tape is resistant to moisture, chemicals, and UV exposure, making it an excellent choice for outdoor and high-performance environments. Its versatility allows it to be used in both temporary and permanent applications, enhancing its appeal to users.

On the other hand, the 3M X70 tape is designed with a focus on ease of use and quick application. It is ideal for less demanding tasks where a strong yet gentle adhesive is required. The X70 tape offers an exceptional balance between adhesion and removability, making it suitable for projects where surface protection is essential. This includes applications in painting, surface protection, and temporary signage. The tape's low-profile design ensures that it can be easily applied without adding bulk, making it a favorite among professionals seeking efficiency.

Both the X80 and X70 tapes utilize 3M’s advanced adhesive technology, which is a hallmark of the brand. This technology ensures reliable performance under a variety of conditions, providing users with confidence in their adhesives. The tapes are also designed to be easy to cut and manage, allowing for precise application without the need for specialized tools.

In summary, the 3M X80 and X70 tapes are exceptional products that stand out for their unique features and capabilities. The X80 is tailored for rigorous applications requiring unmatched durability, while the X70 excels in versatility and ease of use. With 3M's commitment to quality and innovation, both products are set to enhance productivity and performance in various industries.