External Control Device Setup
25. PIP Input Select (Command2:y)
GTo select input source for sub picture in PIP mode.
Transmission
[k][y][ ][Set ID][ ][Data][Cr]
Data 0: | RGB | 1: | Component |
|
2: | Video | 3: | 4: DVI |
Acknowledgement
[y][ ][Set ID][ ][OK][Data][x]
26. Abnormal State (Command2:z)
G To recognize an abnormal state.
Transmission
[k][z][ ][Set ID][ ][FF][Cr]
Data FF:Read
Acknowledgement
[z][ ][Set ID][ ][OK][Data][x]
Data 0: Normal (Power on and signal exist)
1:No signal (Power on).
2:Turn the monitor off with remote control.
3:Turn the monitor off with Sleep Time function.
4:Turn the monitor off with
5:5V down.
6:AC down.
7:Turn the monitor off with Fan Alarm function.
8:Turn the monitor off with Off Time function.
9:Turn the monitor off with Auto Off function.
a:Turn the monitor off with AV board detect.
27.ISM Method (Command2:p)
G To avoid having a fixed image remain on screen.
Transmission
[j][p][ ][Set ID][ ][Data][Cr]
Data | 0: Normal | 2: Orbiter | |
| 1: White wash | 3: Inversion | |
Acknowledgement |
|
| |
|
|
|
|
[p][ | ][Set ID][ ][OK][Data][x] |
|
|
|
|
|
|
28. Low Power (Command2:q)
G To control the low power function on/off.
Transmission
[j][q][ ][Set ID][ ][Data][Cr]
Data 0: Low power off 1: Low power on
Acknowledgement
[q][ ][Set ID][ ][OK][Data][x]
29. Orbiter Time Setting (Command2:r)
G To adjust orbiter operation time term.
Transmission
[j][r][ ][Set ID][ ][Data][Cr]
Data Min: 1 ~ Max: FE
Acknowledgement
[r][ ][Set ID][ ][OK][Data][x]
30. Orbiter Pixel Setting (Command2:s)
G To adjust pixel number in orbiter function. Transmission
[j][s][ ][Set ID][ ][Data][Cr]
Data Min: 0 ~ Max: 9
Acknowledgement
[s][ ][Set ID][ ][OK][Data][x]
31.Picture Size Setting for Twin Picture mode (Command2:t)
G To adjust main picture size in twin picture mode.
Transmission
[j][t][ ][Set ID][ ][Data][Cr]
Data Min: 0 ~ Max: 64
•Refer to ‘Real Data Mapping1’. See page 27. Acknowledgement
[t][ ][Set ID][ ][OK][Data][x]
32. Auto Configure (Command2:u)
G To adjust picture position and minimize image shaking automatically. Auto Configure only works in
Transmission
[j][u][ ][Set ID][ ][Data][Cr]
Data 1: To set
Acknowledgement
[u][ ][Set ID][ ][OK][Data][x]
30 Plasma Monitor