Item

 

 

Specification

 

 

 

 

 

 

 

 

USB Port

2 Ports, electronically fused

 

USB Type A connector

 

USB Rev 1.0

 

 

 

 

 

DL405 I/O Expansion Port

Future use

 

 

 

 

 

Expansion Slot

4 Slots

 

 

 

 

Maximum size of board

 

PCI/ISA slot x 1:

4.8H x 13.3L (inches)

 

 

 

122H x 338L (mm)

 

PCI slot x 2

4.8H x 7.1L (inches)

 

 

 

122H x 180L (mm)

 

 

 

4.8H x 6.7L (inches)

 

 

 

122H x 170L (mm)

 

ISA slot x 1

4.8H x 7.3L (inches)

 

 

 

122H x 185L (mm)

 

 

 

 

RTC/CMOS Backup

Lithium battery (on the CPU board)

 

Battery life of 7 years (77°F - 25_C)

 

 

 

 

LED Indicator

2 Indicators

 

 

PWR: On when the DC power supply provides

 

5VDC to the CPU board

 

HDD: On when the internal HDD is accessed

 

 

 

 

Reset Switch

1 Switch

 

 

 

 

 

Fan

5VDC

 

 

 

 

 

Terminal Block for the Ex-

 

 

 

ternal Power Supply

AC Power

 

 

 

 

94-120VAC/190-240VAC

 

AC Power

 

 

 

 

 

LG: Logic ground

 

G: Frame ground

 

Logic ground and frame ground

 

are internally connected

 

 

 

 

Image 20
Contents D4-470 Trademarks Table of Contents Appendix a European Union Directives CE Manual Revisions IiiIntroduction to the D4-470 This ChapterManual Overview Special Symbols ChaptersAppendices Provides CE informationProcessor D4-470 OverviewPentium Configuration Choices Accessories Installation, Wiring, and Specifications Mounting and Wiring Guidelines Approvals EnclosuresAgency Power Wiring Ports and Connectors Left SideRight Side Technical and Environmental Specifications General Specifications of the D4-470Functional Specifications Functional Specifications cont’d Dimensions Installing Hardware Accessories Adding Third-Party Boards to Expansion Slots Knock-out PanelsInstalling Additional RAM Memory InstallingMemory Dual In-line Memory ModulePowering Internal and External Devices Changing the CPUEuropean Union Directives CE This AppendixEuropean Union EU Directives Member Countries Applicable Directives ComplianceEMC Directive Standards Revelant to PLCs Product Specific Standard for PLCsBasic EMC Installation Guidelines British Standards Institution Sales DepartmentSchaffner Equi-potential Grounding Communications Shielded CablesShielded Cables within Enclosures Network Isolation Items Specific to the D4-470 Maintenance of the D4-470