Mitsubishi Electronics XD8100U manual Execution procedure of RS-232C commands via LAN

Page 17

5.Execution procedure of RS-232C commands via LAN

When the RS-232C command is executed via LAN, a 32-byte connection certification data must be added before the RS-232C command.

To create a 32-byte certification data, following information and procedure are required.

Random character string for creating the certification data that is acquired from the projector (8 characters)

Network password of the projector (1 to 32 characters)

MD5 hash calculation

Based on the above, the execution procedures to connect to the projector and send the RS-232C commands are described below.

1.Connect to Port 63007 of the projector from the PC as a TCP/IP client.

2.After completing the connection, send the acquisition request for the certification data (“$AK ”) from the

PC to the projector.

3.Acquire “$AK******** ” on the PC as the response of the request sent in Step 2. (********: Random charac- ter string for creating the certification data)

4.Create the data for the certification on the PC.

Create the key of the certification data by linking the data acquired in Step 3 with the network charac- ter string.

For example, when the random character string is 12345678 and the password is ABCD, the key of the certification data is 12345678ABCD (character string in ASCII code).

Run MD5 hash on the key of the certification data.

Create the certification data by converting the hash-calculated 16-byte data into the ASCII code char- acter string.

Example:

Calculation result: [4f][3c][5d][a1][7b][4f][b5][ed][2c][99][4e][bb][f6][57][67][54] (hexadecimal numeral)

Certification data: 4f 3c 5d a1 7b 4f b5 ed 2c 99 4e bb f6 57 67 54 (character string in ASCII code)

5.Send the RS-232C command with the certification data from the PC to the projector.

Example:

To send the PON command (00! ) using the certification data created in Step 4:

4f3c5da17b4fb5ed2c994ebbf657675400!

6.Receive the response from the projector on the PC. Response data has the following patterns.

Normal: 00! (Parameter is added depending on the command.)

Error in the certification data: PRV=ERRA

Command error: 00!:N

PC

Projector

1. Connection

2. Acquisition request of the certification data

3. Receiving of the certification data

4. Creation of the certification data

5. Sending of the RS-232C command

6. Receiving of the response data

You can change the password using the NETWORK PASSWORD in the NETWORK menu.

The default password is “admin.”

You can skip the certification process by changing the setting of the NETWORK CERTIFICATION in the NETWORK menu.

When you use a LAN function, set the STANDBY MODE to “STANDARD.” Refer to the operation manual of the projector for setting the STANDBY MODE.

17

Image 17
Contents PC-controllable functions CommandCompatibility with the former models ConnectionCommunications format ACK/NAK Control command configurationCommand for Power on is sent to END RS-232C control flowchartMethod of checking state of projector Reading command diagram Command list Operation commandsLamp 1 Time LOW ResolutionLamp 2 Time LOW Next Lamp RelayZOOM/FOCUS Super ResolutionLens Shift GeometryHORIZ. Curved ARC VERT. Curved ARC KSHBright Uniformity KsrstMULTI-SCREEN Gamma Mode Color Enhancer CEU2B USER-GAMMA Mode Color Enhancer CEU1BSuper Resolution DHD Super Resolution DhdlvAuto Power on Apon Lens Shift Reset LsrstAuto Power OFF Apof Mode DVI Long Cable DviclvManual Reset Color Matching Msml Reset Color Matching CMCMeasure Reset Aspect ALL SIGNALS, 1 Video onlyCinema Mode Password Function PslockVideo Signal SET UP STU00APON1 00CEU1GS2 Pass Password lock commandsExecution procedure of RS-232C commands via LAN