Indicators
This projector has two indicators, each of which shows the operation condition of the projector.
The following offer solutions to possible problems. If these problem persist, turn the projector off and consult your
dealer.
POWER indicator STATUS indicator
ENGLISH
Normal condition
POWER | STATUS | CONDITION | NOTE | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| ||
Steady |
| Off |
| ||||||||||
|
|
| |||||||||||
red |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| Lamp | The POWER button cannot be used to | |
Steady | Blinking | ||||||||||||
| switch between on and off. | ||||||||||||
green | green |
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| The power is on. (Normal condition) |
| |
|
|
|
|
|
|
|
|
|
|
|
| ||
Steady | Steady |
| |||||||||||
|
| ||||||||||||
green | green |
|
| ||||||||||
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Abnormal condition
POWER | STATUS | CONDITION | POSSIBLE SOLUTION | ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Abnormal temperature |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Steady |
|
|
|
|
|
|
|
|
| • The ventilation grilles is clogged with dust or dirt. | • Clean the ventilation grilles. | ||||||||
| green |
|
|
|
|
|
|
|
|
| • The room temperature is high. | • Relocate the projector to a cooler place. | |||||||
|
| or | Blinking orange |
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Steady red |
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| The protection circuit is working or the lamp is in an | • Wait until the STATUS indicator goes out, |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Steady red |
|
|
|
|
|
|
|
|
| abnormal condition. | then press the POWER button. | ||||||||
Blinking green |
| • If the above solution is not effective, | |||||||||||||||||
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| replace the lamp. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Lamp operation time warning. (Total lamp operation | Replace the lamp. |
Steady | Blinking green/red | time reached 1500 hours*1 while the power was on.) | Change with a new lamp if this problem | ||||||||||||||||
| green |
|
|
|
|
|
|
|
|
|
| recurs. | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Lamp operation time warning. (Total lamp operation | |
Steady red | Blinking red | time reached 1500 hours*1 while the power was off.) |
| ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Lamp operation time warning. (Total lamp operation |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Steady red | Steady red | time reached 2000 hours*1, *2 while the power was off.) |
| ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Off | The lamp cover isn’t closed. | Close the cover correctly. | |||||
Blinking |
|
|
|
|
| ||||||||||||||
green/red |
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Abnormal. | Contact your dealer. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| Steady |
|
| |||||||
Blinking |
|
|
|
| or |
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
| |||||||||
green/red |
|
|
|
|
|
|
|
|
|
|
| ||||||||
Blinking |
|
| |||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
*1 When LAMP MODE of the INSTALLATION menu is set to STANDARD. When it is set to LOW, this duration will be extended.