Mitsubishi Electronics HL650U manual Setting range differs depending on the input signals

Page 6

ITEM

ASCII

 

 

HEX

 

VALUE

HOLD

HLD

48h

4Ch 44h

0

(OFF), 1 (ON)

HOLD BEGIN

HLB

48h

4Ch 42h

00–99

HOLD END

HLE

48h

4Ch 45h

00–99

HOLD

HLD

48h

4Ch 44h

0

(OFF), 1 (ON)

HOLD BEGIN

HLB

48h

4Ch 42h

00–99

HOLD END

HLE

48h

4Ch 45h

00–99

CLAMP POSITION

CLP

43h

4Ch 50h

001–255

CLAMP WIDTH

CLW

43h

4Ch 57h

01–63

VERT. SYNC

VSC

56h

53h

43h

0

(OFF), 1 (AUTO)

LPF

LPF

4Ch 50h 46h

0

(OFF), 1 (ON)

SHUTTER(U)

SHU

53h

48h

55h

00–20

SHUTTER(L)

SHL

53h

48h

4Ch

00–20

SHUTTER(LS)

SHLS

53h

48h

4Ch 53h

00–20

SHUTTER(RS)

SHRS

53h

48h

52h 53h

00–20

*1) Setting range differs depending on the input signals.

Some commands are not executed depending on the input signal. The operational restrictions same as those on the menu setting are applied. Refer to “Menu operation” in the User Manual for more details.

How to set the value

Use the ASCII or HEX code as shown below to set the value.

ASCII

‘+’

‘-’

‘0’

‘1’

‘2’

‘3’

‘4’

‘5’

‘6’

‘7’

‘8’

‘9’

HEX

2Bh

2Dh

30h

31h

32h

33h

34h

35h

36h

37h

38h

39h

[Example 1] When setting the AUTO POWER ON to ON. (Figures and symbols enclosed in quotation marks are ASCII codes.):

Sending commands

Status code

Description

from the PC, etc.

from the projector

 

30 30 41 50 4F 4E 31 0D

 

Command for setting the AUTO

‘0’ ‘0’ ‘A’ ‘P’ ‘O’ ‘N’ ‘1’ ‘ ’

 

POWER ON to ON

 

30 30 41 50 4F 4E 31 0D

Command receipt confirmation

 

‘0’ ‘0’ ‘A’ ‘P’ ‘O’ ‘N’ ‘1’ ‘ ’

(Command echo back)

[Example 2] When setting the CONTRAST R of the COLOR TEMP.-USER to +10, the CONTRAST G to 0, and the CONTRAST B to -5. (Figures and symbols enclosed in quotation marks are ASCII codes.):

Sending commands

 

Status code

Description

from the PC, etc.

 

from the projector

 

30 30 50 2B 31 30 2B 30 30 2D 30 35 0D

 

Command for setting the picture

‘0’ ‘0’ ‘P’ ‘+’ ‘1’ ‘0’ ‘+’ ‘0’ ‘0’ ‘-’ ‘0’ ‘5’ ‘

 

control

 

 

30 30 50 2B 31 30 2B 30 30 2D 30 35 0D

Command receipt confirmation

 

 

‘0’ ‘0’ ‘P’ ‘+’ ‘1’ ‘0’ ‘+’ ‘0’ ‘0’ ‘-’ ‘0’ ‘5’ ‘ ’

(Command echo back)

 

 

 

 

[Example 3] When checking the TINT setting (when the TINT is set to +10). (Figures and symbols enclosed in quotation marks are ASCII codes.):

Sending commands

Status code

Description

from the PC, etc.

from the projector

 

30 30 53 0D

 

Command for checking the TINT

‘0’ ‘0’ ‘S’ ‘ ’

 

setting

 

30 30 53 2B 31 30 0D

Check result (+10)

 

‘0’ ‘0’ ‘S’ ‘+’ ‘1’ ‘0’ ‘ ’

 

 

 

 

[Example 4] When setting the GAMMA MODE of the COLOR ENHANCER-USER to DETAIL. (Figures and symbols enclosed in quotation marks are ASCII codes.):

Sending commands

 

Status code

Description

from the PC, etc.

 

from the projector

 

30 30 43 45 55 31 47 53 32 0D

 

 

Command for setting the picture

‘0’ ‘0’ ‘C’ ‘E’ ‘U’ ‘1’ ‘G’ ‘S’ ‘2’ ‘

 

control

 

 

30 30 43 45 55 31 47 53 32 0D

Command receipt confirmation

 

 

‘0’ ‘0’ ‘C’ ‘E’ ‘U’ ‘1’ ‘G’ ‘S’ ‘2’ ‘ ’

(Command echo back)

 

 

 

 

6