Controlling the Monitor with a PC (RS-232C)

You can control this monitor from a PC via RS-232C (COM port) on the PC.

You can also connect multiple monitors via a daisy chain by using a PC. By assigning ID numbers to each monitor (see page 13), you can make input mode selection/adjustment or can check the status of a specific monitor.

Caution

To control the monitor via RS-232C, set RS-232C/LAN SELECT to RS-232C.

You cannot use RS-232C and LAN control simultaneously.

PC connection

„One-to-one connection with a PC

Connect with RS-232 straight cable between the PC’s COM port (RS-232C connector) and the RS-232C input terminal on the monitor.

Communication conditions

Set the RS-232C communication settings on the PC to match the monitor’s communication settings as follows:

Baud rate

9600 bps

 

Stop bit

1 bit

 

 

 

 

 

Data length

8 bits

 

Flow control

None

 

 

 

 

 

Parity bit

None

 

 

 

 

 

 

 

 

Communication procedure

„Command format

When a command is sent from the PC to the monitor, the monitor operates according to the received command and sends a response message to the PC.

 

 

 

 

 

 

 

 

 

 

Return code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C1

 

C2

C3

 

C4

 

P1

P2

P3

P4

 

 

 

 

 

 

 

 

 

 

 

 

Command field

 

 

 

Parameter field

 

 

 

(4 prescribed

 

 

(4 character string comprised of:

alphanumerical characters)

 

0-9, +, -, space, ?)

RS-232C input terminal

PC

To COM port

RS-232 straight cable (commercially available)

„Daisy chain connection… Advanced operation

Connect with RS-232 straight cable between the PC’s COM port (RS-232C connector) and the RS-232C input terminal on the first monitor.

Next, connect RS-232 straight cable to the first monitor’s RS-232C output terminal and to the second monitor’s RS-232C input terminal. Connect in the same way to the third and subsequent monitors.

Up to 25 monitors can be connected. (Depending on the length of the cable used and the surrounding environment.)

First monitor

 

Second monitor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS-232C input terminal

RS-232C output terminal

Example: VOLM0030

VOLM 30

*Be sure to input 4 characters for the parameter. Pad with spaces (“ ”) if necessary.

(“ ” is a return code (0DH, 0AH or 0DH)) Wrong : VOLM30

Right : VOLM

30

When inputting a negative value, specify a numerical value in three digits.

Example: AUTR-009

Do not use spaces for MPOS, DATE, and SC01 through SC08. Specify parameters using a specified number of characters.

Example: MPOS010097

If a command has “R” listed for “DIRECTION” in the “RS-232C command table” on page 16, the current value can be returned by using “?” as the parameter.

Example:

VOLM ? ? ? ?

From PC to monitor (How much

is current volume setting?).

30

From monitor to PC (Current

volume setting: 30).

*If an ID number (see page 13) has been assigned (For example, ID number = 1).

VOLM

? ←

From PC to monitor.

30 001

From monitor to PC.

PC

To COM port

RS-232 straight cables

(commercially available)

 

E12

Image 12
Contents Operation Guide Contents Basic Operation MuteMenu DisplayBasic Operation „Switching the screen size Wide Zoom NormalDot by Dot Cut offMenu Items Displaying the menu screen„Example of operation „Menu screen display„SETUP Menu item details„SCREEN „PICTURE„OPTION „ENLARGE PC input „PIP/PbyP„Dual screen display Power „Enlarge„SCHEDULE ENLARGE-POSAdjustments for PC screen display „Automatic adjustment„Screen display for adjustment „ADVANCED items AV input See11 E Communication procedure Controlling the Monitor with a PC RS-232CPC connection Communication conditions13 E „Response code format„ID numbers Wait ← „Repeater control command Volume settings for all monitors are returned15 E Controlling the Monitor with a PC RS-232C „Repeater controlRS-232C command table Power control/Input mode selectionHow to read the command table Controlling the Monitor with a PC RS-232C17 E Controlling the Monitor with a PC RS-232C Picture menuAudio menu Controlling the Monitor with a PC RS-232C Setup menu Option menuImage Position Epos setting 19 EHorizontal orientation Vertical orientation Initialization/Functional Restriction Setting Function menu Controlling the Monitor with a PC RS-232C PIP/PbyP menuOthers Settings to connect to a LAN Controlling the Monitor with a PC LAN21 E „ To set on the monitorThis monitor is factory preset as shown below IP Address Default Gateway 0.0Controlling the Monitor with a PC LAN „ To set from a PC 23 E Controlling with a PCControlling the Monitor with a PC LAN „ Basic operationStandby mode, Power on is the operation available „ Information„ Control „ Network LAN Setup 25 E„ Network Security „ Network General „ Mail Originator27 E „ Mail Recipient„ Mail Periodical „ Service & Support URL Information URL InformationSpecify the condition to display the URL M O 29 EMitsubishi Contact Information North America