Indicators
This projector has two indicators, each of which shows the operation condition of the projector.
The following offer solutions to possible problems. If these problem persist, turn the projector off and consult your dealer.
STATUS indicator | POWER indicator |
Normal condition
POWER | STATUS | CONDITION | NOTE | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Off |
| |||
|
|
|
|
|
|
| ||||
Steady red |
| |||||||||
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Off | Power up process (About 4 seconds) |
| ||
Blinking red |
| |||||||||
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| The power is on. (Normal condition) |
|
|
|
|
|
|
|
|
|
|
| |
Steady green | Steady green |
|
|
• Lamp cooling down. (About 90 seconds)
•Lamp lit up (About 60 seconds)
Steady green | Blinking green |
Abnormal condition
POWER | STATUS |
| CONDITION |
| POSSIBLE SOLUTION | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Off | Blinking green about | Lamp failure |
| • | Replace the lamp and reset the lamp hour. | ||||||||
|
| 30 seconds after |
|
|
|
| |||||||||
|
|
|
|
|
| power on. |
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Color wheel failure |
| • | Contact your dealer. |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Steady green | Steady amber |
| |||||||||||||
about 5 seconds after |
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
| power on. |
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| • Check if the fan is clogged with dust or dirt and | |
|
|
|
|
|
| Steady green about | Fan failure |
|
| clean it. | |||||
|
|
|
|
|
|
| • If the above solution is not effective, contact your | ||||||||
Blinking green | 20 seconds after |
|
| ||||||||||||
|
|
| dealer. | ||||||||||||
|
|
|
|
|
| power on. |
|
|
| ||||||
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| • Clean the ventilation grilles. | |
|
|
|
|
|
|
|
|
|
|
|
|
|
| • Relocate the projector to a cooler place. | |
|
|
|
|
|
|
|
|
|
|
|
|
|
| • For the directly shut down, it will check the | |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| temperature first, if it's too high, it will start |
|
|
|
|
|
| Steady red about 10 | Abnormal temperature |
|
| cooling for 90 seconds. | |||||
Steady green | seconds after power |
|
| • | If it's abnormal shut down in the previous time, | ||||||||||
|
|
| while the temperature is too high, it will start the | ||||||||||||
|
|
|
|
|
|
|
| on. |
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| cooling process after 90 seconds when the | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| temperature is still too high. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 95% Lamp life exceed |
| • | Replace the lamp and reset the lamp hour. |
Steady green | Blinking red |
| |||||||||||||
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Lamp life end |
| • | Replace the lamp and reset the lamp hour. | |||||
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
| Steady red about 5 |
| ||||||||
|
| Off | seconds after power |
|
|
|
| ||||||||
|
|
|
|
|
|
|
| on. |
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| N/A |
| N/A | Lamp cover open |
| • | Put back the lamp cover. | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|