3.5.3Composite Pass Through (Toggle) (Not available from IR remote mouse)

This control determines whether the Composite television input on Channel A is routed through to Channel B or not.

If the signal is “passed through” Composite television that is input on Channel A will appear as an output on Channel B. If the signal is not passed through, Channel B Composite television will be configured as a second Composite television input. The default is Channel B configured as an input.

Composite Channel B Configuration is indicated by “COMP B=PASS” or “COMP B=IN” on the QuadScan’s Front Panel Display.

3.6Output Sync Signal Configuration

3.6.1Output Sync Signal Configuration (Multiple) (Not available from IR remote mouse)

This control determines where output video synchronization signals will be placed

Output Sync

Front Panel Designation

Separate H and V (pins 13 and 14)

Osync= 5WIRE

Separate Composite (pin 14)

Osync= 4WIRE

Composite Sync on Green (pin 2)

Osync= 3WIRE

The Default is Separate Composite Sync (H and V) on pin 2.

3.7Display Device Configuration

3.7.1Display Device Configuration (Multiple) (Not available from IR remote mouse)

The Display Device Configuration operates in conjunction with the Input Aspect Ratio and the Output Screen Aspect Ratio to provide the correct scaling for the particular output. Several resolutions are supported as follows:

Resolution

Aspect Ratio

Mode Title

720 x 480 (NTSC)

4:3

DBL TV

720 x 576 (PAL)

4:3

DBL TV

640 x 480

4:3

VGA

800 x 600

4:3

SVGA

1024 x 768

4:3

XGA

720 x 720 (NTSC)

16:9

TRIPLE TV

720 x 864 (PAL)

16:9

TRIPLE TV

720 x 960 (NTSC)

16:9

QUAD TV

720 x 1152 (PAL)

16:9

QUAD TV

1280 x 720

16:9

HDTV

1365 x 1024

4:3

D-ILA

The Default is DBL TV **

TView QuadScan User's Manual 0092-5000-200

19

Image 19
Contents USER’S Manual Page Introduction Page Intent of this Manual IntroductionStandard Packout for QuadScan Desktop SKU #444-5524 QuadScan FamilyDesktop or Rackmount Standard Packout for QuadScan Desktop SKU #444-55205 RS-232/422 Control Standard Packout for QuadScan Rackmount SKU #444-5522Output Resolutions Operational SpecificationsInput Signal Formats Output Signal FormatsPhysical Size Signal Routing CapabilityPower Consumption Control MethodsProduct Ordering Options Available Accessories for the QuadScanOrdering Guide QuadScan Desktop Back Plate Diagram InstallationQuad Scan Desktop Version Installation Page Quad Scan Rackmount Version Installation Page Component Level QuadScan Control FunctionsOutput Screen Aspect Ratio Reset and Control FunctionsMode Reset Full Reset Not available from IR remote mouseVHS Pass Through Toggle Not available from IR remote mouse Signal RoutingMotion Processing Motion Processing MultipleDisplay Device Configuration Output Sync Signal ConfigurationInput Source Selection Multiple TerminationInput Source Selection VGA Termination Toggle Not available from IR remote mouseSaturation Range Input Television Video FunctionsBrightness Range Contrast RangeInput Television Window Control Output Window ControlInput Horizontal and Vertical Position Range Input Horizontal and Vertical Size Range Input Aspect Ratio SelectionInput Aspect Ratio Selection Multiple Front Panel Control QuadScan Control MethodsLocking the Front Panel Mode Reset with the IR Remote Control IR Remote ControlRemote Control Interface RS-232/422 Control Configuring the QuadScan for RS-232 or RS-422RS-232 Recommended RS-232 Wiring Connecting the QuadScan to communications devicesSelecting the QuadScan’s address Sending Communications Commands to the QuadScanRegister Name Reg # Type Value Byte Action HexaDecimal Byte Page Appendix a Limited Warranty