Elmo HV-7100SX instruction manual Main Camera, Lighting, Sxga, Xga

Page 54

Main Camera

1

Item

 

 

 

Specifications

 

 

 

 

Lens

 

f = 7.2 – 72mm (10 - time zoom), F3.1

 

Shooting speed

 

15 frames / sec

 

 

2

Shooting area

 

SXGA

362mm 290mm (14.5 11.6 in.) max.

(H V)

 

 

41mm 33mm (1.6 1.3 in.) min.

 

 

 

 

XGA

380mm 285mm (15.2 11.4 in.) max.

 

 

 

 

 

43mm 32mm (1.7 1.3 in.) min.

3

Limit of focus adjustment

From the stage surface to 100mm (3.9 in) above the stage surface

Zooming

 

Powered (with double speed function)

Focusing

 

Auto / Manual

 

 

 

 

 

 

 

Iris

 

Auto (with level adjustment) / Manual

4

Image pick-up element

1/1.8CCD

 

 

Total picture elements

1688(H) 1248(V), 2,110,000 pixels

 

Effective picture element

SXGA 1525(H) 1220(V)

XGA 1600(H) 1200(V)

 

Sync. system

 

Internal sync.

 

 

5

Resolution

 

Analog RGB output :

Horizontal 900TV lines or more;

 

 

 

 

 

Vertical 900TV lines or more

 

 

 

Video output :

Horizontal 470 TV lines or more

 

 

 

 

 

 

SXGA (negative polarity) XGA (positive polarity)

 

Analog RGB output

0.7V (P-P)

75unbalanced, Synchronization signal,

6

 

 

 

Signal frequency

 

 

 

 

 

SXGA:

Horizontal frequency 63.981 kHz, Vertical frequency 60.020 Hz

 

 

 

 

 

(1280 1024 at 60 Hz); Compliant with VESA

 

 

 

 

XGA:

Horizontal frequency 48.363 kHz, Vertical frequency 60.004 Hz

 

 

 

 

 

(1024 768 at 60 Hz); Compliant with VESA

7

Composite video output

Compliant with NTSC/PAL

 

S-video output

 

Compliant with NTSC/PAL

 

 

 

 

 

White balance

 

Full auto / One-push / Manual

 

 

Video output selection

Provided (NTSC / PAL)

 

8

Posi/Nega conversion

Provided

 

 

 

Color/B&W selection

Provided

 

 

 

 

Image rotation

 

Provided (0° / 90° / 180° / 270°)

 

Contrast

 

Provided

 

 

 

9

Gamma selection

 

Provided (1.0 / 0.9 / 0.8 / 0.7 / 0.6 / 0.5 / 0.4 / 0.3)

Aperture selection

 

Provided

 

 

 

 

Pause

 

Provided

 

 

 

 

Electronic image enlargement

Provided (2, can be scrolled)

 

10

Pointer

 

Controllable by mouse (color selectable)

F.A.M.

 

Provided

 

 

 

 

Drawing function

 

Provided

 

 

 

 

Split screen function

Provided

 

 

 

11

Lighting

 

 

 

 

 

 

 

 

 

 

 

 

 

Item

 

 

 

 

Specifications

 

Upper

 

High frequency lighting mode, 3-wave-length type fluorescent lamp

 

 

 

6W (Model: FHL6EX-N)

 

 

 

Base

 

High frequency lighting mode, 3-wave-length type fluorescent lamp

 

 

 

Area size: 296mm (W) 216mm (H) (11.7 8.5 in.)

53

Image 54
Contents HV-7100SX Important Safeguards Wash hands after handling Should be moved with care. QuickRisk Electric Shock Do not Open Exclamation point within Before YOU USE Contents Symptoms and Confirmation Replacement of Fluorescent Lamp Operation Procedures Various Function and OperationsSetting Up Cable Connection Data Format Specifications OSD MenuPart Names and Functions AppearanceFront Operation Panel Name Function Reference PauseTo change the output line To select F.A.M INPUT.RGB1 Rear PanelOUTPUT.RGB OUT CD-ROMWireless Remote Control RGB1/2 DIP SwitchINPUT.RGB2 Electronic Status PRESET.SETPause Memory noWireless Remote Control Receivable RangePreparation Mouse Mouse OperationSetting UP and Connection Setting UpConnection to Monitor and Projector Analog RGB Signal Storing StoringOperation Procedures Turn on the power switchSimple steps for Presenting Printed Material Steps for Showing Transparent Material WideVarious Functions and Operation LightingZoom Monitor Output Selection Table of Video- and Audio-in / out Terminal SelectionsVGA1 Electronic Enlargement Mouse can be operated as followsColor / B&W Selection Posi / Nega ConversionImage Rotation PauseContrast White Balance AutoONE-PUSH Auto iris adjustment IrisManual iris adjustment Focus Auto FocusPowered Manual Focus Preset Operation Image Memory M. Frame Accumulate Mode Splitting the ScreenInstallation of LCD Monitor Connecting to the LCD MonitorUtility Software CD-ROM Enter OSD MenuIcon Name Function Reference Pages To display the OSD menuIcon Name Function Reference Pages Auto Focus To switch the selection Conversion Volume. When the left button Selection Emphasis of the image When power is turned on,M. Frame To switch the image F.A.M Microphone terminalClick the left button on the mouse on a vertex of a Fixing the second pointTo draw a rectangle Rectangle to fix the first point. Then, unclick the leftButton of the mouse, and the eraser color will turn Cursor will be deleted. When the cursor is movedDrawing data should be erased, and click the left From blue to red and the drawing data aroundMarker is on display, bring the pointer to Marker movement will be enabled again. ToShould be fixed, the marker position is fixed. While Marker and click the left button of the mouse,Page On the split screen When Stored Image Call To read out images from MemoryAgain, the image on camera Again, the icon returns to Image read conditionRXD TXD DTR DSR RTS CTS RI CI RS-232C SpecificationsCable Connection RXDResponse data format Visual Presenter → PC Data Format SpecificationsTransmission Command PC → Visual Presenter ACKAUTO31H MANUAL32H Transmission SpecificationsStatus Iris 20H Mode Status ImageUart Communication Format Connection Troubleshooting Hints Symptoms and ConfirmationReplacement of Fluorescent Lamp Specifications GeneralUSB Sxga Main CameraLighting XGASupplied Accessories OptionsOverseas Subsidiary Companies